Chapter 8: Troubleshooting

 

 

 

 

 

 

 

 

 

 

Event

Action

 

 

 

 

 

 

Connection Lost

Normal result of logging out. Also a result of poor

 

 

 

SCSI/FC cable or network connection.

 

 

 

 

 

 

Disk Notification

 

 

 

 

 

 

 

Disk Down

Identify the disk drive involved. Power down the

 

 

 

system, remove and test the drive. Replace the drive

 

 

 

as needed.

 

 

 

 

 

 

Disk Plugged In

A disk drive has been plugged into the enclosure.

 

 

 

Normal.

 

 

 

 

 

 

Disk Access Retry

Watch this disk drive. If problems persist, power down

 

 

 

the system, remove and test the drive. Replace the

 

 

 

drive as needed.

 

 

 

 

 

 

Disk CRC Error

Identify the disk drive involved. Power down the

 

 

 

system, remove and test the drive. Replace the drive

 

 

 

as needed.

 

 

 

 

 

 

Disk SMART Failed

 

 

 

 

 

 

 

Disk ECC Error

Identify the disk drive involved. Power down the

 

 

 

 

 

Disk Bad Sector

system, remove and test the drive. Replace the drive

 

 

 

as needed.

 

 

Disk Reserve Sector Error

 

 

 

 

 

 

Disk Time Out

 

 

 

 

 

 

 

Logical Drive

 

 

 

Notification

 

 

 

 

 

 

 

Create Logical Drive

A new logical drive was created. Normal.

 

 

 

 

 

 

Delete Logical Drive

A logical drive was deleted. Normal.

 

 

 

 

 

 

Logical Drive Critical

If hot-spare is enabled, logical drive will rebuild

 

 

 

automatically with a new disk drive. Identify and

 

 

 

replace the failed drive.

 

 

 

Without a hot spare, the logical drive will attempt to

 

 

 

rebuild the failed drive. If this action repeats, remove

 

 

 

the drive for test and repair or replacement.

 

 

 

 

 

 

Logical Drive Offline

Go to the Promise website and download a document

 

 

 

called Array Recovery Procedures or contact

 

 

 

Technical Support.

 

 

 

 

 

 

Logical Drive Migration

Expansion or RAID level change of logical drive

 

 

Started

begun. Normal.

 

 

 

 

 

 

Logical Drive

 

 

 

Notification, cont.

 

 

 

 

 

 

231

Page 239
Image 239
Promise Technology 15110 user manual Disk Notification, Logical Drive Notification