The reference region is determined according to the following precedence. M/E1 >M/E2 >M/E3 >P/P >USER1 > USER2 > USER3 > USER4 >USER5 > USER6 > USER7 > USER8 > DME1> DME2 > DME3 > DME4 > P-BUS

Master region

The regions saved in a master snapshot register or master timeline register and the register numbers saved in such regions can be recalled at a time as the master region.

The master region can be saved or recalled using the numeric keypad control block.

Registers

A register is an area of memory in a device which holds a snapshot, keyframe, and so on.

Keyframe effect registers

Dedicated effect registers

There are 99 dedicated registers for keyframe effects in each region, numbered 1 to 99.

Shared user-programmable DME registers

In addition to the 99 DME registers for each region (i.e. each channel), there are also shared registers for each processor as shown in the following table. These are used for user-programmable DME.

Register number

Register allocation

 

 

101 to 199

Shared register for one-channel effects

 

 

201 to 299

Shared register for two-channel effects

 

 

Note

When operating with these shared registers, be sure to select the appropriate regions depending on the number of channels. When recalling registers in the 200 range, select two consecutive channels for the regions, as for example [DME1] and [DME2].

Work register

This is a temporary register used when editing keyframes.

Functions 9000-DVS 1 Chapter

Regions and Registers 125