Keys 4 Chapter

• Separate edge off

Knob

Parameter

Adjustment

Setting values

 

 

 

 

1

Width

Width

0.00 to 8.00 a)

 

 

 

(0.00 to 100.00) b)

3

Density

Density

0.00 to 100.00

 

 

 

 

a)In the “4H mode” and when [Fine Key] (page 276) is on, the setting value range is 0.00 to 4.00.

b)When a wipe pattern key or key wipe pattern key is selected as the key type

Separate edge on

The left, right, top, and bottom border or outline widths can be adjusted independently. The separate edge function is only valid when a luminance key, linear key, or chroma key is selected as the key type.

Knob

Parameter

Adjustment

Setting values

 

 

 

 

1

Top

Top edge width

0.00 to 8.00 a)

2

Left

Left edge width

0.00 to 8.00 a)

3

Right

Right edge width

0.00 to 8.00 a)

4

Bottom

Bottom edge width

0.00 to 8.00 a)

5

Density

Density

0.00 to 100.00

 

 

 

 

a)In the “4H mode” and when [Fine Key] (page 276) is on, the setting value range is 0.00 to 4.00.

When drop border or shadow is selected: The setting parameter values depend on the on/off setting of key drop and the selection of 4H mode/ 8H mode (see page 52).

• “Key drop OFF” mode

Knob

Parameter

Adjustment

Setting values

 

 

 

 

 

1

Width

Width

0.00 to

8.00

 

 

 

 

2

Position

Position

359.99 to 180.00

 

 

 

 

 

3

Density

Density

0.00 to

100.00

 

 

 

 

 

• “Key drop ON” mode

Knob

Parameter

Adjustment

Setting values

 

 

 

 

 

1

Width

Width

0.00 to

8.00 a)

2

Position

Position

359.99 to 0.00

 

 

 

 

 

3

Density

Density

0.00 to

100.00

 

 

 

 

 

a)In the “4H mode” and when [Fine Key] (page 276) is on, the setting value range is 0.00 to 4.00.

274 Key Setting Operations Using Menus