Panel Control and Menus 2 Chapter
stop it there, then press this button to set the pattern limit range. This button is enabled when the [PTN LIMIT] button is off.
PTN (pattern) LIMIT: When a wipe or DME wipe is selected, pressing this button, turning it on, enables the pattern limit function.
fKey status display
For each of keys 1 and 2, when the key is inserted, the corresponding ON indicator lights. The OVER indicators show the priority between keys 1 and 2, by lighting when the corresponding key is on top. For example, when key 1 appears over key 2 on the program monitor, the OVER indicator for key 1 lights.
The following is the Flexi Pad control block.
gMode selection buttons
WIPE: When saving or recalling a wipe snapshot, use this in combination with the buttons of the memory recall section.
DME: When saving or recalling a DME wipe snapshot, use this in combination with the buttons of the memory recall section.
SNAPSHOT: When saving or recalling a snapshot, use this in combination with the buttons of the memory recall section.
hMemory recall section
This consists of eight buttons with LCDs, whose display changes according to the operation mode. Use these in combination with the mode selection buttons to save, recall, or delete wipe snapshots, DME wipe snapshots, or snapshots.
iUNDO button
After recalling a register, press this button to return to the state before recalling the register.
jXPT HOLD
A bus for which
kNumeric display
Depending on the operation mode, this shows a wipe or DME wipe pattern number, or a register number in up to four digits.
202 Names and Functions of Parts of the Control Panel