Functions
mask source.
When the box generator is selected, a rectangular mask is formed. You can adjust the positions of the four sides of the box separately.
When the pattern generator is selected, you can select the pattern and apply modifiers.
Sub mask: This uses the wipe generator signal or the signal selected on the utility 1 bus on the M/E or PGM/PST bank, as the mask source.
When the wipe generator is selected, the patterns and the pattern modifiers are the same as in a wipe transition.
Key Memory
The key memory function allows the keyer settings on each
There are two modes for key memory: simple mode and full mode. The parameters stored in each mode are as follows.
Simple mode: key type, clean mode (including the plane setting for chroma keying), key position, key inversion, and adjustment values for the particular key type (Clip, Gain, Density, Filter, etc. This includes color vector key, wipe pattern key, key wipe pattern key, and chroma key. However, in the case of a chroma key, it excludes color cancel, Y balance, foreground CCR, window, and shadow.)
Full mode: All settings except transition (the same parameters as simple mode, [Fine Key], key modifiers, main and sub mask settings, chroma key detailed settings, and so on)
Key Snapshots
Key settings other than the key on/off status and the key priority can all be instantaneously saved in a dedicated register, for recall when required. A key snapshot comprises three values: a
For details of key snapshot operations, see “Key Snapshots” (page 299).
Blink
The blink function provides the following effects.
54 Keys