GPI Output: Set the GPI output ports and trigger polarities, and make the action settings.

Setup Relating to DCU Input/Output

In DCU setup, carry out settings particular to the DCU.

You can make the following settings.

Input Config: Assign GPI inputs to Parallel input ports.

GPI Input Assign: Make GPI input settings.

Output Config: Assign GPI outputs to parallel output ports inserted in an option slot.

GPI Output Assign: Make GPI output settings.

Serial Port Assign: Set the protocol to match the devices connected to a 9- pin serial port. You can also select the control panel used to control each device.

Setup Relating to the Router Interface and Tally Interface

Carry out settings relating to the interface with the routing switcher, and settings relating to the tally interface.

You can make the following settings.

Router interface setup (Router)

These settings are common to the parallel tally and serial tally.

Matrix Size: Assign the switcher matrix of each switcher processor to S-Bus space, and select the matrix size and positioning level, source address settings, and so on.

External Box: To obtain the signal selection status of external devices with a parallel input, assign a matrix as an external selector in the S-Bus space. Make the matrix size, assignment level, source address, and other settings.

Tally interface setup (Tally)

Group tally settings (Group Tally)

Tally Group: Select the group tally (Gp1 to 4 or Gp5 to 8) which can be used.

S-Bus Tally Enable: Specify S-Bus tally enabled or disabled.

Functions 9000-DVS 1 Chapter

Setup 155