Setup Engineering 16 Chapter

3 Set the source.

Source From: Specify the source start address for the wiring configuration.

Source Level: Specify the source level for the wiring configuration.

Knob

Parameter

Adjustment

Setting values

 

 

 

 

4

Source (From)

Source start address

1 to 1024

 

 

 

 

5

Source (Level)

Source level

1 to 8

 

 

 

 

4 Press [Execute].

This makes the wiring setting according to the specifications in steps 2 and 3.

Changing the wiring settings

Use the following procedure.

1 In the Router/Tally>Wiring menu, press [Modify].

The Modify menu appears.

2 Referring to steps 2 and 3 in the preceding section “Making new wiring settings,” change the parameters as required. In this case, however, it is not possible to specify multiple destinations in a single operation, and a single “Destination Address” must be specified.

3 Press [Execute].

This updates the wiring settings.

Deleting wiring settings

Use the following procedure.

1 In the Router/Tally>Wiring menu, using either of the following methods, select the wiring whose settings you want to delete.

Press directly on the list appearing in the status area.

Press the arrow keys to scroll the reverse video cursor.

2 Press [Delete].

This deletes the selected wiring entry.

282 Setup Relating to Router Interface and Tally