Setup Engineering 16 Chapter

Setup Relating to Router Interface and Tally

Router Interface Settings (Router Menu)

In this system, the interface with a router (routing switcher) uses the S-Bus protocol. It is therefore necessary to assign inputs and outputs of the switcher and so on to an S-Bus space.

To carry out this assignment, use the Router/Tally>Router menu. The assignment is common to the parallel and serial tallies.

To display the Router menu

In the Engineering Setup menu, select VF6 ‘Router/Tally’ and HF1 ‘Router.’ The status area shows the device names to be assigned to the S-Bus space, the matrix size, source address, destination address, and level.

Assigning switcher inputs and outputs to S-Bus space

Use the following procedure.

1 In the <Device> group of the Router/Tally>Router menu, select the device to which the settings apply.

SWR1: Settings apply to switcher 1.

SWR2: Settings apply to switcher 2.

Note

When there are two switchers on the same network, the SWR2 (second switcher) settings are required. If there is only one switcher, the settings are not required.

2 In the <Matrix Size> group, select the matrix size.

Standard (136 138): Assign the switcher S-Bus space at full size. You can assign all switcher inputs and outputs to the S-Bus space, but this causes some waste of S-Bus space.

Compact (128 128): Assign the switcher S-Bus space at compact size. It is not possible to assign all switcher inputs and outputs to the S-Bus space, but the S-Bus space can be used efficiently.

3 Turn the knobs to set the parameters for the following items.

Source: Specify the start address of the matrix source.

Destination: Specify the start address of the matrix destination.

278 Setup Relating to Router Interface and Tally