To display the Output menu

In the Engineering Setup menu, select VF3 ‘Switcher’ and HF3 ‘Output.’ The status area shows the signal numbers and names, and output signal phase for the signals output from Output 1 to 48.

Assigning output signals

To assign a signal to output from an output port, use the following procedure.

1 In the Switcher>Output menu, press [Output Assign].

The Output Assign menu appears.

The status area shows the output ports and assigned signals on the left, and a list of signals that can be assigned on the right.

2 In the <Output Assign> group, select any of the following.

[Re-Entry Source]: It is possible to make duplicate assignments. M/E-1 Output 1 to 6 a)

M/E-2 Output 1 to 6 a)

M/E-3 Output 1 to 6 a) PGM/PST 1 to 6 a)

DME Monitor Video DME Monitor Key

a) M/E output signals selected in the M/E Output Assign menu.

[Aux Bus]: It is not possible to make duplicate assignments. Preset

Edit Preview AUX 1 to 48

3 Using any of the following methods, select the output port number and signal to be assigned.

Press directly on the list appearing in the status area to make the

 

selection.

 

 

 

Press the arrow keys to scroll the reverse video cursor.

Turn the knobs to make the selection.

 

 

 

 

 

 

Knob

Parameter

Adjustment

 

Setting values

 

 

 

 

 

 

1

 

Output No

Output port number

 

1 to 48

 

 

 

 

 

 

2

 

Source No

Selection of signal to be assigned

 

 

 

 

 

 

 

 

For output ports not to be assigned, press [Inhibit].

 

The selected signal appears in reverse video.

Setup Engineering 16 Chapter

Setup Relating to Switcher Processor

241