In the <Device> group of the Router/Tally>Parallel Tally menu, select DCU1 or DCU2.

1

2 Using any of the following methods, select the slot number and port number.

Press directly on the list appearing in the status area.

Press the arrow keys to scroll the reverse video cursor.

Turn the knobs to make the setting.

Knob

Parameter

Adjustment

Setting values

 

 

 

 

1

Slot No

Parallel tally slot number

2 to 6

 

 

 

 

2

Port No

Parallel tally port number

1 to 54

 

 

 

 

3 Press [Set].

The Set menu appears.

4 In the <Source/Destination> group, select the tally type.

Src: Return a tally to all sources output to the destination.

Dest: Return a tally to the destination outputting the source to which a source tally is returned.

5 Set the destination address and level.

The level setting is only required when in step 4 you selected Destination.

Knob

Parameter

Adjustment

Setting values

 

 

 

 

1

Address

Destination address

1 to 1024

 

 

 

 

2

Level

Destination level

1 to 8

 

 

 

 

6 When setting the tally type, set the following parameters.

Knob

Parameter

Adjustment

Setting values

 

 

 

 

3

Type

Tally type

1 to 8 a)

a)When you selected Group1 to 4 in the section “Setting the tally groups” (page 280), this is 1:R1, 2:G1, 3:R2, 4:G2, 5:R3, 6:G3, 7:R4, and 8:G4.

When you selected Group5 to 8, this is 1:R5, 2:G5, 3:R6, 4:G6, 5:R7, 6:G7, 7:R8, and 8:G8. (R is an abbreviation of “Red Tally,” and G of “Green Tally.”)

7 Press [Execute].

This makes the parallel tally settings, in accordance with the settings in steps 1 to 6.

Setup Engineering 16 Chapter

Setup Relating to Router Interface and Tally

287