Setup Relating to DCU

Note

For setup relating to DCU, it is necessary to make the same settings on multiple control panels (maximum three units) that are sharing the DCU. After carrying out the DCU setup on one control panel, make the same settings on the other control panels.

Settings Relating to Parallel Inputs (Input Config Menu)

The DCU parallel input ports are assigned with the following priority sequence.

1.When external boxes are set in the Router/Tally>Router>External Box Assign menu, the parallel inputs are assigned to the external box inputs in order.

2.When tally settings are carried out in the Router/Tally>Tally Enable menu, tally inputs are assigned automatically.

In this menu, you set only the input ports which are unused after making the above assignments.

To assign GPI inputs to DCU parallel input ports, display the DCU>Input Config menu.

To display the Input Config menu

In the Engineering Setup menu, select VF5 ‘DCU’ and HF1 ‘Input Config.’ The status area shows input port information.

Assigning a GPI input port

Use the following procedure.

1 In the DCU>Input Config menu, select what the setting applies to (DCU1 or DCU2) from the <DCU Select> group.

2 In the <Parallel Input Assign> group, press [GPI Input].

3 Using any of the following methods, assign the number of the GPI input to the input port.

Press directly on the list appearing in the status area.

Press the arrow keys to scroll the reverse video cursor.

Turn the knobs to make the setting.

Setup Engineering 16 Chapter

Setup Relating to DCU 265