2 Select the M/E you want to logically set to the PGM/PST from the <Logical M/E to Physical P/P> group.

P/P: assign the physical PGM/PST as logical PGM/PST.

M/E-1:assign the physical PGM/PST as logical M/E-1.

M/E-2:assign the physical PGM/PST as logical M/E-2.

M/E-3:assign the physical PGM/PST as logical M/E-3.

Signal Input Settings (Input Menu)

For setup relating to signal inputs, use the Switcher>Input menu.

To display the Input menu

In the Engineering Setup menu, select VF3 ‘Switcher’ and HF2 ‘Input.’ The status area shows source numbers and source names, input signal phase, and through mode on/off setting.

Making phase adjustment and through mode settings

Use the following procedure.

1 In the Switcher>Input menu, select the input signal to which the settings apply.

Press directly on the list appearing in the status area.

Press the arrow keys to scroll the reverse video cursor.

Turn the knob to make the setting.

Knob

Parameter

Adjustment

Setting values

 

 

 

 

1

Src No

Input signal selection

1 to 80

 

 

 

 

The selected input signal appears in reverse video.

2 Press [Input Phase Adj].

3 To adjust the phase, adjust the following parameter.

Knob

Parameter

Adjustment

Setting values

 

 

 

 

2

Phase

Input signal phase

16 to +16

 

 

 

 

Setup Engineering 16 Chapter

Setup Relating to Switcher Processor

239