Set the MKS-8080/8082 station number in the range 2 to 17. This can be done on the MKS-8080/8082 separately.

Setup Engineering 16 Chapter

Simple Connection of the MKS-8080/8082 AUX Bus Remote Panel

Procedure for Simple Connection

To carry out simple connection of the MKS-8080/8082 AUX Bus Remote Panel, use the following procedure.

For settings on the MKS-8080/8082, refer to the section “Making the Setting With Buttons (Setup Function)” in the Operation Manual for the MKS-8080/ 8082.

1 Carry out initialization of the MKS-8080/8082 settings. This can be done on the MKS-8080/8082 separately.

2

3 Set the S-BUS data link primary station to the CCP-8000 Center Control Panel.

Set the STATION ID switches S903 on the front of the CA-45 board in the SCU SLOT 1 to 001 (switch 1 only to the OPEN position).

4 In the Engineering Setup> System> Initialize menu, select PNL, and carry out a reset.

This carries out a restart, and when the restart is completed connection to the MKS-8080/8082 is possible.

5 In the Engineering Setup>Router/Tally> Router menu, set the position of the DVS-9000 system in S-BUS space.

Select the setting from SWR1 and SWR2, and set each of Source,

Destination, and Level to 1.

Setting Status of the MKS-8080/8082 in Simple Connection

As a result of making the simple connection, the MKS-8080/8082 operates in AUX bus mode, and the settings are the following factory defaults.