Setup Engineering 16 Chapter

To assign the output of each bank in Multi Program mode

When you selected [Multi Program] in the procedure described in “Setting the operation mode” (page 235), use the following procedure.

1 In the Switcher>Config menu, press [M/E Output Assign].

The M/E Output Assign menu appears.

2 On the list in the status area, select the bank output to be assigned.

The selected output appears in reverse video.

3 In the <M/E Output Assign> group, select the output signal to be assigned.

To set the output configuration for each bank

When you selected [Multi Program] or [DSK] in the procedure described in “Setting the operation mode” (page 235), use the following procedure.

1 In the Switcher>Config menu, press [PGM Config].

The PGM Config menu appears.

The status area shows the background and key configuration assigned to the output of each bank.

2 Using either of the following methods, select the output for which you want to make the setting.

Press directly on the list appearing in the status area.

Press the arrow keys to scroll the reverse video cursor.

The selected output appears in reverse video.

3 In the <Bkgd> group, select the background.

In Multi Program mode, select [Clean] or [Utility2], then skip to step 5. In DSK mode, select one of [Bkgd1] to [Bkgd4].

4 In DSK mode, turn the knobs to select the background signal.

Knob

Parameter

Adjustment

Setting values

 

 

 

 

2 to 5

Bkgd1 to 4

Background signal selection

1 to 18 a)

a)1 to 6: M/E1 OUT1 to 6

7 to 12: M/E2 OUT1 to 6

13 to 18: M/E3 OUT1 to 6

236 Setup Relating to Switcher Processor