Not lit: Register not containing anything

4 To apply an attribute, hold down the [SNAPSHOT] button, and in the memory recall section, press a button as follows, turning it on.

Attribute to apply

Button

 

 

Effect dissolve

[EFF DISS] button

 

 

Auto transition

[AUTO TRANS] button

 

 

For details of attributes and available attributes, see “Snapshot

Attributes” in Chapter 1 (Volume 1).

Note

In the Flexi Pad control block, it is not possible to apply the cross-point hold or GPI output attributes. In a simple type Flexi Pad control block, it is not possible to apply any attributes. To add these attributes, use a menu operation. (See page 170.)

5 Still holding down the [SNAPSHOT] button from step 4, press the memory recall button corresponding to the register in which you want to save.

Note

If you press a button which is lit orange or yellow, the existing register contents are overwritten.

The button you pressed lights yellow, and this completes the save operation. The [STORE STATS] button lights amber, and the numeric display shows the selected register number after the bank number.

To cancel a snapshot save operation

After saving a snapshot, to cancel the save, hold down the [STORE STATS] button and press the [UNDO] button.

The [STORE STATS] button changes color from amber to green.

Note

On a simple type Flexi Pad control block, it is not possible to cancel a snapshot save operation.

Recalling a snapshot from a Flexi Pad control block

As an example, to recall a snapshot on the M/E-1 bank, use the following procedure.

Snapshots 14 Chapter

Snapshot Operations in the Flexi Pad Control Block 167