Teledyne API - T300/T300M and M300E/EM PN 04906H (DCN5840)

APPENDIX A-2: Setup Variables For Serial I/O

Setup Variable

Numeric

 

Default

Value

 

Units

 

Value

Range

FILT_ASIZE

Samples

48,

1–1000

 

 

20

3, 8,

 

 

 

40

20, 22

 

 

 

 

 

 

FILT_DELTA

PPM

4,

 

1–1000

 

 

0.7 5

 

 

 

15

3, 8

 

 

 

0.15 9, 12

 

 

 

0.4 19, 23

 

 

 

0.2 20, 22

 

FILT_PCT

%

10

 

1–100

 

 

5 20, 22, 23

 

FILT_DELAY

Seconds

90,

0–180

 

 

72

20, 22

 

FILT_ADAPT

ON

ON, OFF

 

 

 

 

CO2_DWELL 10

Seconds

0.1

0.1–30

 

 

 

 

CO2_FILT_ADAPT 10

ON

ON, OFF

 

 

 

 

 

CO2_FILT_SIZE 10

Samples

48

 

1–300

CO2_FILT_ASIZE 10

Samples

12

 

1–300

 

 

 

 

 

CO2_FILT_DELTA 10

%

2

 

0.01–10

 

 

 

 

 

CO2_FILT_PCT 10

%

10

 

0.1–100

 

 

 

 

 

CO2_FILT_DELAY 10

Seconds

90

 

0–300

 

 

 

 

 

CO2_DIL_FACTOR 10

1

 

0.1–1000

 

 

 

 

 

O2_DWELL 14

Seconds

1

 

0.1–30

 

 

 

 

O2_FILT_ADAPT 14

ON

ON, OFF

 

 

 

 

 

O2_FILT_SIZE 14

Samples

60

 

1–500

 

 

 

 

 

O2_FILT_ASIZE 14

Samples

10

 

1–500

 

 

 

 

 

O2_FILT_DELTA 14

%

2

 

0.1–100

 

 

 

 

 

O2_FILT_PCT 14

%

2

 

0.1–100

 

 

 

 

 

O2_FILT_DELAY 14

Seconds

20

 

0–300

 

 

 

 

 

O2_DIL_FACTOR 14

1

 

0.1–1000

 

 

 

 

 

Description

Moving average filter size in adaptive mode.

Absolute change to trigger adaptive filter.

Percent change to trigger adaptive filter.

Delay before leaving adaptive filter mode.

ON enables adaptive filter; OFF disables it.

Dwell time before taking each sample.

ON enables CO2 adaptive filter; OFF disables it.

CO2 moving average filter size.

CO2 moving average filter size in adaptive mode.

Absolute CO2 conc. change to trigger adaptive filter.

Percent CO2 conc. change to trigger adaptive filter.

Delay before leaving CO2 adaptive filter mode.

Dilution factor for CO2. Used only if is dilution enabled with FACTORY_OPT variable.

Dwell time before taking each sample.

ON enables O2 adaptive filter; OFF disables it.

O2 moving average filter size in normal mode.

O2 moving average filter size in adaptive mode.

Absolute change in O2 concentration to shorten filter.

Relative change in O2 concentration to shorten filter.

Delay before leaving O2 adaptive filter mode.

Dilution factor for O2. Used only if is dilution enabled with FACTORY_OPT variable.

A-9