SCHEDULE Table 20-3

20.3HOW TO CONFIGURE THE SCHEDULE TABLE

Defoe a SCHEDULE Table with a matching number for each COS to be used in the PORT and USER Tables.

Each SCHEDULE Table consists of eight possible time periods (numbered 1 through 8) and a default period. Specify for each time period:

The days of the week (or HOL for holiday)

The times of the day to start and end (in 24-hour time)

The number of the INFORhMTION Table to use

Since the default period cOvers all times not specified, only define the lNFORhL4TION Table.

g3’ A default INFORMATION Table is required for each SCHBDULB Table.

The Toshiba VP System contains 128 (O-127) SCHEDULE Tables equal to the number of COS.

Enter each time period requiring a different INFORMAlION Table. The remaining times use the INFORhLATION Table defined as the default.

If a SCHEDULE Table has only a default (no time periods), press Is/ when the program asks for the INFORMATION Table for the first time period. Then enter the default INFORhfATION Table number.

An INFORMATION Table number may be assigned to any or several SCHEDULE entries. Several SCHEDULE Tables and/or entries within a SCHEDULE Table may reference the Same INFORMATION Table.

All INFORMATION Tables referenced by the SCHBDULE Tables must be defined before they are entered into the SCHEDULE Table. Before the Toshiba VF’ System accepts the entry into the SCHEDULE Table, it verifies that an lMORMATION Table exists.

H Using INSTALL

An empty SCHEDULE Table is displayed for each COS defined in the PORT and USER Tables. Enter the appropriate times, days, and INFORMATION Table number for each SCHEDULE able time period displayed. When finished with the time periods, enter an INFORMATION Table to be used for the default times.

Page 270
Image 270
Toshiba VP 300S manual HOW to Configure the Schedule Table