Avaya G450, G250 manual Port Configuration 802.1X Tab, STP Path Cost, STP Force Migration

Models: G450 G250

1 305
Download 305 pages 47.91 Kb
Page 54
Image 54

Device Configuration

Table 14: Port Configuration Dialog Box - Advanced Tab (continued)

Field

Description

 

 

STP Admin Path

The administratively assigned value for the contribution of this port to

Cost

the path cost of paths towards the spanning tree root. A value of 0

 

assigns the automatically calculated default Path Cost value to the

 

port.

 

STP Admin Path Cost complements STP Path Cost, which returns

 

the operational value of the path cost.

 

 

STP Path Cost

The operational cost factor used by Spanning Tree Algorithm to

 

determine the most efficient route for forwarding traffic to its

 

destination while removing loops in the network.For more

 

information, refer to Spanning Tree Algorithm (STA) in The Reference

 

Guide.

 

 

STP Priority

The priority factor used by STP to determine the activity status of an

 

individual port on the Spanning Tree.

 

 

STP Force Migration

When checked and in RSTP mode, the port is forced to transmit

 

RSTP BPDUs.

 

 

Port Classification

The classification of a specific port. Port Classification allows network

 

managers to specify each port level’s importance. The possible

 

states are:

 

Regular - Normal Users

 

Valuable - Servers or critical users.

 

For more information refer to Port Classification in The Reference

 

Guide.

 

 

 

2 of 2

 

 

For more information on the user interface, refer to “Using Dialog Boxes and Tables” on page 32.

Port Configuration - 802.1X Tab

802.1x port security requires a user connected to a port on the network to be authenticated by an authentication server.

When a user connects to a port configured with 802.1x port security, the port forwards an authentication packet to a Radius authentication server. The authentication server checks if the user is authorized to use the port, and either allows or blocks the user’s access to the port.

The port can be configured to automatically reauthenticate the user. If the reauthentication fails, the user is denied further access to the port. For more information, refer to “Port Configuration - General Tab” on page 49.

54 Avaya Integrated Management Release 4.0.1 Software Update Manager

Page 54
Image 54
Avaya G450, G250 manual Port Configuration 802.1X Tab, STP Path Cost, STP Force Migration, Port Classification