Avaya G450 Port Configuration Power Fields Description Administrative, Detection Status, Critical

Models: G450 G250

1 305
Download 305 pages 47.91 Kb
Page 70
Image 70

Power over Ethernet

The following table provides a list of the fields in the Power tab of the Module Configuration dialog box and their descriptions:

Table 21: Port Configuration - Power Fields

Field

Description

 

 

Administrative

The administrative state of the port in terms of power management.

Status

Possible states include:

 

Enable - This port can supply power to IP telephones.

 

Disable - This port cannot supply power to IP telephones.

 

 

Detection Status

The operational status of port power detection. Possible states

 

include:

 

Searching - This port is currently being polled.

 

Delivering Power - This port is supplying power to an IP

 

telephone.

 

Fault - This port is currently not supplying power to an IP

 

telephone due to a fault condition on the port.

 

Disabled - This port is currently not configured to supply

 

power to an IP telephone.

 

Test - This port is being tested for its ability to deliver power.

 

Other Fault - This port is currently not delivering power to an

 

IP telephone due to a fault condition other than on the port.

 

 

Power Priority

The priority of the port in terms of power management. When the

 

demand for power exceeds the modules capacity, ports with lower

 

priority will be prevented from supplying power before ports with a

 

higher priority. Possible priorities include:

 

Critical

 

High

 

Low

 

 

Power Consumption

The power consumption of the port in milliwatts.

(mW)

 

70 Avaya Integrated Management Release 4.0.1 Software Update Manager

Page 70
Image 70
Avaya G450 Port Configuration Power Fields Description Administrative, Detection Status, Power Priority, Critical, High