Using the Token Ring Bridge and Port Configuration Windows 2-67
Bridging
Figure 2-21. Port ConÞguration Window
The Bridge ConÞguration and Port ConÞguration window Þelds are deÞned as
follows:
Bridge Number
Displays and allows you to set the number assigned to Token Ring bridge. This
value is limited to the hexadecimal range of 0 through F. This Þeld is settable in
the Bridge ConÞguration window and read-only in the Port ConÞguration
window.
Virtual Ring Number
Displays and allows you to set the number of the target segment connected to the
selected bridge. This value is limited to the hexadecimal range of 001 through FFF.
This Þeld is settable in the Bridge ConÞguration window and read-only in the
Port ConÞguration window.
Ring Number
Displays and allows you to set the segment number that uniquely identiÞes the
segment to which this port is connected. This value is limited to the hexadecimal
range of 001 through FFF. This Þeld appears in the Port ConÞguration window
only.