CONTROL SET POINT AND CONFIGURATION LOG

CONTROL SET POINT AND CONFIGURATION LOG

Model Number: _____________________________

Software Versions: ___________________________

Serial Number: ______________________________

MBB: CESR131320−− _ _

Date: ______________________________________

ECB: CESR131249−− _ _

Technician: _________________________________

MARQ: CESR131171−− _ _

INDICATE UNIT SETTINGS BELOW

Control Type:

Thermostat/T55 Space Temp./T−56 Space Temp./T−58 Space Temp.

Set Points:

Cooling

Occupied: _______________

Unoccupied: __________________

 

Heating

Occupied: _______________

Unoccupied: __________________

MODE — CONFIGURATION

48/50PG and PM

ITEM

EXPANSION

RANGE

UNITS

DEFAULT

CONFIGURATION

 

 

 

 

DISP

Display Configuration

 

 

 

METR

Metric Display

Off/On

 

Off

LANG

Language Selection

0=English

 

0

 

 

1=Spanish

 

 

 

 

2=French

 

 

 

 

3=Portuguese

 

 

PROT

Password Enable

Disable/Enable

 

Enable

PSWD

Service Password

0000 to 9999

 

1111

TEST

Test Display LEDs

Off/On

 

Off

UNIT

Unit Configuration

 

 

 

S.DLY

Startup Delay

10 to 600

sec

30

U.CTL

Unit Control Type

2=Thermostat

 

2

 

 

3=Space

 

 

 

 

Sensor

 

 

T.CTL

Thermostat Control Type

0=Adaptive

 

0

 

 

1=1 Stage Y1

 

 

 

 

2=2 Stage Y1

 

 

 

 

3=Digital

 

 

OC.FN

Fan On When Occupied

No/Yes

 

Yes

IDF.F

Shut Down on IDF Failure

No/Yes

 

Yes

FN.SW

Fan Status Switch

0=No Switch

 

0: no FIOP

 

 

1=Normal

 

1: FIOP

 

 

Open

 

 

 

 

2=Normal

 

 

 

 

Closed

 

 

FL.SW

Filter Status Switch

0=No Switch

 

0: no FIOP

 

 

1=Normal

 

1: FIOP

 

 

Open

 

 

 

 

2=Normal

 

 

 

 

Closed

 

 

FS.SW

Fire Shutdown Switch

0=No Switch

 

0: no FIOP

 

 

1=Normal

 

1: FIOP

 

 

Open

 

 

 

 

2=Normal

 

 

 

 

Closed

 

 

RM.SW

Remote Occupancy

0=No Switch

 

0

 

Switch

1=Normal

 

 

 

 

Open

 

 

 

 

2=Normal

 

 

 

 

Closed

 

 

SAT.T

SAT Settling Time

10 to 900

sec

240

RAT.S

RAT Sensor on SPTO In­

No/Yes

 

No

 

put

 

 

 

RH.S

RH Sensor on OAQ Input

No/Yes

 

No

RH.SW

Space Humidity Switch

0=No Switch

 

0: no Humidi­MiZer

 

 

1=Normal

 

FIOP

 

 

Open

 

1: Humidi­MiZer

 

 

2=Normal

 

FIOP

 

 

Closed

 

 

TCS.C

Temp Cmp Strt Cool

0 to 60

mins

0

 

Factr

 

 

 

TCS.H

Temp Cmp Strt Heat

0 to 60

mins

0

 

Factr

 

 

 

CCN TABLE/

SUB-TABLE

SERVICE CONFIGURATION

DISPLAY

(display only, not in table)

UNIT

CCN POINT

PAGE NO.

14

14

DISPUNIT 14

LANGUAGE 14

PASS_EBL 14

PASSWORD 14

DISPTEST 14

14

STARTDLY 14

CTL_TYPE 14

STATTYPE 15

OCC_FAN 15

FATALFAN 15

FANSTCFG 15

FILSTCFG 15

SHTDNCFG 15

REMOCCFG 15

SAT_SET 15

RAT_SPTO 15

RH_OAQ 15

HUMSTCFG 15

TCSTCOOL 15

TCSTHEAT 15