Chapter 4 ParametersContent

Content

Address

Function

Status

 

Error code:

 

 

monitor

2100H

0: No error occurred

Read only

 

 

 

1: Over-current (oc)

 

 

 

 

 

 

 

2: Over-voltage (ov)

 

 

 

 

 

3: IGBT Overheat (oH1)

 

 

 

 

 

4: Reserved

 

 

 

 

 

5: Overload (oL)

 

 

 

 

 

6: Overload1 (oL1)

 

 

 

 

 

7: Overload2 (oL2)

 

 

 

 

 

8: External fault (EF)

 

 

 

 

 

9: Current exceeds 2 times rated current during accel (ocA)

 

 

 

 

 

10: Current exceeds 2 times rated current during decel (ocd)

 

 

 

 

 

11: Current exceeds 2 times rated current during steady state

 

 

operation (ocn)

 

 

 

 

 

12: Ground Fault (GFF)

 

 

 

Status

 

13: Reserved

monitor

 

 

 

14: PHL (Phase-Loss)

Read only

 

 

 

 

2100H

15: Reserved

 

 

 

 

 

16: Auto accel/decel failure (cFA)

 

 

 

 

 

17: Software protection enabled (codE)

 

 

 

 

 

18: Power Board CPU WRITE failure (CF1.0)

 

 

 

 

 

19: Power Board CPU READ failure (CF2.0)

 

 

 

 

 

20: CC, OC Hardware protection failure (HPF1)

 

 

 

 

 

21: OV Hardware protection failure (HPF2)

 

 

 

 

 

22: GFF Hardware protection failure (HPF3)

 

 

 

 

 

23: OC Hardware protection failure (HPF4)

 

 

 

 

 

24: U-phase error (cF3.0)

 

 

 

 

 

25: V-phase error (cF3.1)

 

 

 

 

 

26: W-phase error (cF3.2)

 

 

 

 

 

27: DCBUS error (cF3.3)

 

 

 