Chapter 2 Installation and Wiring

 

 

Terminal

Terminal Function

 

 

 

Factory Settings (NPN mode)

 

 

 

 

Symbol

 

 

 

 

 

ON: Connect to DCM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MI5

Multi-function Input 5

 

ON: the activation current is 5.5mA.

 

 

 

 

OFF: leakage current tolerance is 10μA.

 

 

 

 

 

 

 

 

MI6

Multi-function Input 6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+24V

DC Voltage Source

 

+24VDC, 50mA used for PNP mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

DCM

Digital Signal Common

 

Common for digital inputs and used for NPN

 

 

 

mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RA

Multi-function Relay output

Resistive Load:

 

 

 

 

 

(N.O.) a

 

5A(N.O.)/3A(N.C.) 240VAC

 

 

 

 

 

 

 

 

 

5A(N.O.)/3A(N.C.) 24VDC

 

 

 

Multi-function Relay output

 

 

RB

Inductive Load:

 

 

(N.C.) b

 

1.5A(N.O.)/0.5A(N.C.) 240VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.5A(N.O.)/0.5A(N.C.) 24VDC

 

 

RC

Multi-function Relay common

 

 

Refer to Pr.03.00 for programming

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+10V

Potentiometer power supply

+10VDC 3mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Analog voltage Input

Impedance:

47kΩ

 

 

 

+10V

AVI circuit

 

 

 

 

Resolution:

10 bits

 

 

 

 

 

 

 

 

AVI

 

Range:

0 ~ 10VDC/4~20mA =

 

 

AVI

 

 

 

 

 

 

0 ~ Max. Output Frequency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Pr.01.00)

 

 

 

ACM

internal circuit

Selection:

Pr.02.00, Pr.02.09, Pr.10.00

 

 

 

 

Set-up:

Pr.04.14 ~ Pr.04.17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ACM

Analog control signal

Common for AVI= and AFM

 

 

(common)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 to 10V, 2mA

 

 

 

 

 

 

 

 

Impedance:

47Ω

 

 

 

Analog output meter

Output current

2mA max

 

 

 

ACM circuit

 

Resolution:

8 bits

 

 

 

 

AFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AFM

 

 

Range:

0 ~ 10VDC

 

 

 

0~10V

Function:

Pr.03.03 to Pr.03.04

 

 

 

 

potentiometer

 

 

 

 

Max. 2mA

 

 

 

 

 

 

 

 

 

 

 

internal circuit ACM

 

 

 

NOTE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The voltage output type for this analog signal is

 

 

 

 

 

 

 

 

 

 

PWM. It needs to read value by the movable coil

 

 

 

 

 

meter and is not suitable for A/D signal conversion.

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: Control signal wiring size: 18 AWG (0.75 mm2) with shielded wire.