Delta Electronics VFD-EL manual DC Brake Time, 08.00, 08.01, 08.02, 08.03

Models: VFD-EL

1 209
Download 209 pages 9.33 Kb
Page 120
Image 120
08.00

 

 

 

Chapter 4 Parameters

Group 8: Special Parameters

 

 

 

 

08.00

DC Brake Current Level

Unit: 1

 

Settings

0 to 100%

Factory Setting: 0

 

 

 

 

This parameter sets the level of DC Brake Current output to the motor during start-up and stopping. When setting DC Brake Current, the Rated Current (Pr.00.01) is regarded as 100%. It is recommended to start with a low DC Brake Current Level and then increase until proper holding torque has been achieved.

08.01

DC Brake Time during Start-up

Unit: 0.1

 

Settings

0.0 to 60.0 sec

Factory Setting: 0.0

 

 

 

 

This parameter determines the duration of the DC Brake current after a RUN command. When the time has elapsed, the AC motor drive will start accelerating from the Minimum Frequency (Pr.01.05).

08.02

DC Brake Time during Stopping

Unit: 0.1

 

Settings

0.0 to 60.0 sec

Factory Setting: 0.0

 

 

 

 

This parameter determines the duration of the DC Brake current during stopping. If stopping with DC Brake is desired, Pr.02.02 Stop Method must be set to 0 or 2 for Ramp to Stop.

08.03

Start-Point for DC Brake

 

 

 

 

 

Unit: 0.01

 

Settings

 

 

 

0.00 to 600.0Hz

 

 

 

Factory Setting: 0.00

This parameter determines the frequency when DC Brake will begin during deceleration.

 

Output Frequency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start-Point for

DC Brake Time

 

 

 

 

 

 

 

 

 

 

 

DC Brake

 

 

 

 

 

 

 

 

 

 

 

during Stopping

 

 

 

 

 

 

 

 

 

 

 

Time during

 

 

 

 

 

 

 

 

0 1.0 5

 

 

 

 

 

 

 

 

 

 

 

 

 

Stopping0 8.0 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ru n/Stop

ONOFF

DC Brake Time

Revision August 2008, 2ELE, V1.02

4-77