Delta Electronics VFD-EL manual Parameter

Models: VFD-EL

1 209
Download 209 pages 9.33 Kb
Page 52
Image 52
Manual background

 

 

Chapter 4 Parameters

 

Parameter

Explanation

Settings

Factory

Customer

Setting

03.10

Reserved

 

 

 

 

 

 

 

 

03.11

Brake Release

0.00 to 20.00Hz

0.00

 

Frequency

 

 

 

 

 

 

 

 

 

 

03.12

Brake Engage

0.00 to 20.00Hz

0.00

 

Frequency

 

 

 

 

 

 

 

 

 

 

03.13

Display the Status of

Read only

##

 

 

Relay

 

 

 

Group 4 Input Function Parameters

 

 

 

 

 

 

 

Parameter

Explanation

Settings

Factory

Customer

Setting

04.00

Keypad

0.0 to 100.0 %

0.0

 

Potentiometer Bias

 

 

 

 

 

 

 

 

 

 

04.01

Keypad

0: Positive bias

00

 

Potentiometer Bias

1: Negative bias

 

 

Polarity

 

 

 

 

 

 

 

 

 

 

 

04.02

Keypad

0.1 to 200.0 %

100.0

 

Potentiometer Gain

 

 

 

 

 

 

 

 

 

 

 

Keypad

0: No negative bias command

 

 

 

Potentiometer

 

 

04.03

 

0

 

Negative Bias,

 

 

 

Reverse Motion

1: Negative bias: REV motion enabled

 

 

 

Enable/Disable

 

 

 

 

 

 

 

 

 

 

 

04.04

2-wire/3-wire

0: 2-wire: FWD/STOP, REV/STOP

 

 

 

Operation Control

1: 2-wire: FWD/REV, RUN/STOP

0

 

 

Modes

 

 

 

2: 3-wire operation

 

 

 

 

 

 

 

04.05

Multi-function Input

0: No function

1

 

 

Terminal (MI3)

1: Multi-Step speed command 1

 

 

 

 

 

 

 

 

2: Multi-Step speed command 2

 

 

 

 

 

 

 

04.06

Multi-function Input

3: Multi-Step speed command 3

2

 

 

Terminal (MI4)

4: Multi-Step speed command 4

 

 

 

 

 

 

 

 

5: External reset

 

 

 

 

 

 

 

04.07

Multi-function Input

6: Accel/Decel inhibit

3

 

 

Terminal (MI5)

7: Accel/Decel time selection command

 

 

 

 

 

 

 

 

8: Jog Operation

 

 

 

 

 

 

 

Revision August 2008, 2ELE, V1.02