Chapter 4 Parameters

 

 

resistor value (Ω)

 

 

 

 

1330

 

 

 

 

 

550

 

 

 

 

 

 

 

 

 

 

 

 

Tr

temperature ()

 

 

 

Tr-5Tr+5

 

 

 

 

07.15

Motor PTC Overheat Warning Level

 

Unit: 0.1

 

Settings

0.1~10.0V

 

Factory Setting: 1.2

 

 

 

 

07.16

Motor PTC Overheat Reset Delta Level

 

Unit: 0.1

 

Settings

0.1~5.0V

 

Factory Setting: 0.6

07.17Treatment of the motor PTC Overheat

Factory Setting: 0

Settings

0

Warn and RAMP to stop

 

1

Warn and COAST to stop

 

2

Warn and keep running

 

 

 

If temperature exceeds the motor PTC overheat warning level (Pr.07.15), the drive will act

according to Pr.07.17 and display . If the temperature decreases below the result (Pr.07.15 minus Pr.07.16), the warning display will disappear.

07.13

Input Debouncing Time of the PTC Protection

Unit: 2ms

 

Settings

0~9999 (is 0-19998ms)

Factory Setting: 100

 

 

 

 

This parameter is to delay the signals on PTC analog input terminals. 1 unit is 2 msec, 2 units are 4 msec, etc.

4-76

Revision August 2008, 2ELE, V1.02

Page 119
Image 119