Delta Electronics VFD-EL Vfd-El, Fwd/Stop, Rev/Stop, Run/Stop, Fwd/Rev, MI1CLOSERUN, MI3OPENSTOP

Models: VFD-EL

1 209
Download 209 pages 9.33 Kb
Page 65
Image 65
FWD/STOP

Chapter 4 ParametersREV/STOP

Overheat Warning

Applications

Purpose

 

 

 

 

 

 

 

 

 

Functions

 

 

 

Related

 

 

 

 

 

 

 

 

 

 

 

 

Parameters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air conditioner

Safety measure

When AC motor drive overheats, it

03.00

uses a thermal sensor to have

 

 

 

04.05~04.08

 

 

overheat warning.

 

 

 

 

Two-wire/three-wire

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Applications

Purpose

 

 

 

 

 

 

 

 

 

Functions

 

 

 

Related

 

 

 

 

 

 

 

 

 

 

 

 

Parameters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FWD/STOP

 

 

 

MI1:("OPEN":STOP)

02.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

("CLOSE":FWD)

02.01

 

 

REV/STOP

 

 

 

 

 

MI2:("OPEN": STOP)

 

 

 

 

 

 

02.09

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

("CLOSE": REV)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DCM

 

VFD-EL

 

04.04

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To run, stop,

 

 

 

 

 

 

 

 

 

 

 

 

 

MI1:("OPEN":STOP)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RUN/STOP

 

("CLOSE":RUN)

 

General application

forward and

FWD/REV

 

 

 

 

 

MI2:("OPEN": FWD)

 

 

reverse by external

 

 

 

 

 

 

 

 

 

 

 

 

 

("CLOSE": REV)

 

 

terminals

 

 

 

 

 

 

 

 

 

 

 

 

 

DCM

 

VFD-EL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STOP RUN

3-wire

 

 

 

 

 

 

 

MI1:("CLOSE":RUN)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MI3:("OPEN":STOP)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MI2:("OPEN": FWD)

 

 

 

 

 

 

REV/FWD

 

("CLOSE": REV)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DCM

VFD-EL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation Command

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Applications

Purpose

 

 

 

 

 

 

 

 

 

Functions

 

 

 

Related

 

 

 

 

 

 

 

 

 

 

 

 

Parameters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Selecting the

Selection of AC motor drive control by

02.01

General application

source of control

external terminals, digital keypad or

04.05~04.08

 

signal

RS485.

 

 

 

 

 

 

Frequency Hold

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Applications

Purpose

 

 

 

 

 

 

 

 

 

Functions

 

 

 

Related

 

 

 

 

 

 

 

 

 

 

 

 

Parameters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

General application

Acceleration/

Hold output frequency during

 

 

 

04.05~04.08

deceleration pause

Acceleration/deceleration

 

 

 

 

 

 

 

 

 

4-22

Revision August 2008, 2ELE, V1.02

Page 65
Image 65
Delta Electronics VFD-EL Vfd-El, Fwd/Stop, Rev/Stop, Run/Stop, Fwd/Rev, MI1CLOSERUN, MI3OPENSTOP, MI2OPEN FWD, Close Rev