1.2.1 Ambient Conditions

Chapter 1 IntroductionMinimum Mounting Clearances

1.2.1 Ambient Conditions

Install the AC motor drive in an environment with the following conditions:

 

 

Air Temperature:

 

-10 ~ +50°C (14 ~ 122°F) for UL & cUL

 

 

 

 

-10 ~ +40°C (14 ~ 104°F) for side-by-side mounting

 

 

 

 

 

 

 

 

Relative Humidity:

<90%, no condensation allowed

 

 

 

 

 

 

Operation

Atmosphere

86 ~ 106 kPa

 

 

pressure:

 

 

 

 

 

 

 

Installation Site

<1000m

 

 

Altitude:

 

 

 

 

 

 

Vibration:

 

<20Hz: 9.80 m/s2 (1G) max

 

 

 

 

20 ~ 50Hz: 5.88 m/s2 (0.6G) max

 

 

 

 

 

 

Temperature:

-20°C ~ +60°C (-4°F ~ 140°F)

 

 

 

 

 

Storage

Relative Humidity:

 

<90%, no condensation allowed

 

 

Transportation

Atmosphere

86 ~ 106 kPa

 

 

pressure:

 

 

 

 

 

 

Vibration:

 

<20Hz: 9.80 m/s2 (1G) max

 

 

 

20 ~ 50Hz: 5.88 m/s2 (0.6G) max

 

 

 

 

Pollution

2: good for a factory type environment.

 

Degree

 

 

 

 

 

Minimum Mounting Clearances

Frame A Mounting Clearances

Option 1 (-10 to +50°C)

120mm

50mmManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background50mm

Option 2 (-10 to +40°C)

Air flow

120mm

 

50mm

Air Flow

 

50mm

 

120mm

120mm

1-6