F-99TROUBLESHOOTING & REPAIRF-99

NORMAL WELD VOLTAGE WAVEFORM (STICK CC)

MACHINE LOADED TO 300 AMPS AT 27 VOLTS

Trig +15V

CH1

 

 

0 volts

20V

1ms

This is the typical DC output voltage generated from a properly operating machine. Note that each vertical divi- sion represents 20 volts and that each horizontal division represents 1 millisecond in time.

The machine was loaded with a resis- tance grid bank to 300 amps at 27 volts.

NOTE: Scope probes are connected at weld output terminals.

 

SCOPE SETTINGS

 

Volts/Div

20V/Div

 

 

 

 

Horizontal Sweep

1 ms/Div.

 

 

Coupling

DC

 

 

Trigger

Internal

 