TROUBLESHOOTING & REPAIR
F-51 F-51
RANGER 305D
WARNING
STATORVOLTAGE TESTS
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician
ormachine operatorand will invalidate your factory warranty. For your safety and to avoid
electrical shock, please observe all safety notes and precautions detailed throughout this
manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-
bleshooting assistance before you proceed. Call 1-888-935-3877.
TEST DESCRIPTION
This test will determine if the stator is able to produce correct voltage from of its windings.
Itwill only yield meaning data if the engine highidle speed is correct, (3625 to 3675 RPM),
and approximately 46 to 54 VDC is present across the rotor slip rings.
NOTE: The slip ring voltage will most likely be correct if at least one of theAC output volt-
ages is correct.
MATERIALS NEEDED
Miscellaneous hand tools
Voltmeter
Testpins