F-97TROUBLESHOOTING & REPAIRF-97

NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (120VAC SUPPLY)

HIGH IDLE – NO LOAD 16.4 ms

0 volts

50V5ms

This is the typical auxiliary output voltage generated from a properly operating machine. Note that each vertical division represents 50 volts and that each horizontal division rep- resents 5 milliseconds in time. NOTE: Scope probes are connected at machine 120 VAC receptacle.

 

SCOPE SETTINGS

 

Volts/Div

50V/Div.

 

 

 

 

Horizontal Sweep

5 ms/Div.

 

 

Coupling

DC

 

 

Trigger

Internal

 

RANGER 305D

Page 151
Image 151
Lincoln Electric SVM175-A service manual 97TROUBLESHOOTING & REPAIRF-97, Normal Open Circuit Voltage Waveform 120VAC Supply