F-18 F-18
RANGER 305D
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING & REPAIR
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely,
contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
1-888-935-3877.
PROBLEMS
(SYMPTOMS) POSSIBLE AREAS OF
MISADJUSTMENT(S) RECOMMENDED
COURSE OF ACTION
ENGINE AND IDLE PROBLEMS
7. If the solenoid does not hold in
the low idle position, remove
plug P6 from control PC board
and wait for about 30 seconds.
8. If the engine drops to low idle,
check for damage or a buildup
of conductive materials on or
around the bypass filter assem-
bly and the output terminals.
See wiring diagram.
9. Note: The bypass filter assem-
bly is connected between the
output terminals. See wiring
diagram.
10. If the engine still does not drop
to low idle, the con trol PC
board is probably defective.
Replace it.
CAUTION
Observe Safety Guidelines
detailed in the beginning of this manual. TROUBLESHOOTING GUIDE