F-100 TROUBLESHOOTING & REPAIRF-100
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (WIRE CV TAP)
MAX CONTROL POT - HIGH IDLE - NO LOAD
| 0 volts |
50V | 5ms |
This is the typical DC open circuit out- put voltage generated from a properly operating machine. Note that each vertical division represents 50 volts and that each horizontal division rep- resents 5 milliseconds in time. NOTE: Scope probes are connected at weld output terminals.
| SCOPE SETTINGS | ||
| Volts/Div | 50V/Div. |
|
|
| ||
| Horizontal Sweep | 5 ms/Div. |
|
| Coupling | DC |
|
| Trigger | Internal |
|