TROUBLESHOOTING & REPAIR
F-100 F-100
RANGER 305D
This is the typical DC open circuit out-
put voltage generated from a properly
operating machine. Note that each
vertical division represents 50 volts
and that each horizontal division rep-
resents 5 milliseconds in time.
NOTE: Scope probes are connected
at weld output terminals.
SCOPE SETTINGS
Volts/Div.....................50V/Div.
Horizontal Sweep.....5 ms/Div.
Coupling.............................DC
Trigger.........................Internal
NORMAL OPEN CIRCUIT VOLTAGEWAVEFORM (WIRE CV TAP)

MAX CONTROL POT - HIGH IDLE - NO LOAD

0 volts
50V 5ms