F-102

 

TROUBLESHOOTING & REPAIR

 

 

F-102

 

 

Retest a machine:

 

 

RETEST AFTER REPAIR

 

 

 

 

 

 

 

• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the

 

 

 

machineʼs electrical characteristics. OR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• If you repair or replace any electrical components.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENGINE OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

Mode

 

 

 

 

 

No Load RPM

 

 

 

 

Load RPM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low Idle

 

 

 

2400 - 2500

 

 

 

 

 

 

N/A

 

 

 

 

High Idle

 

 

 

3625 - 3675

 

 

 

 

3350 - 3750

 

 

 

 

 

 

WELDER DC (STICK) OUTPUT (ARC control @ -10)

 

 

 

 

 

 

 

Mode Selector

 

Output Control

 

 

Open Circuit

 

 

Load Volts

 

 

Load Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch

 

 

 

 

 

Volts

 

 

 

 

 

 

 

 

 

 

 

 

Stick (CC)

 

Maximum

 

55-60

 

27-32

 

295-325

 

 

 

 

 

 

WELDER CV (WIRE) OUTPUT (ARC Control @ +10)

 

 

 

 

 

 

 

Mode Selector

 

Output Control

 

 

Open Circuit

 

 

Load Volts

 

 

Load Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch

 

 

 

 

 

Voltage

 

 

 

 

 

 

 

 

 

 

 

 

CV

 

Maximum

 

55-60

 

28-30

 

 

300

 

 

 

 

 

CV

 

Minimum

 

55-60

 

13-15

 

 

120

 

 

 

 

 

 

 

TOUCH START TIG (ARC Control @ +10)

 

 

 

 

 

 

 

 

Mode Selector

 

Output Control

 

 

Open Circuit

 

 

Load Volts

 

 

Load Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch

 

 

 

 

 

Voltage

 

 

 

 

 

 

 

 

 

 

 

 

TIG

 

Maximum

 

10-15

 

20-24

 

 

240-255

 

 

 

 

 

TIG

 

Minimum

 

10-15

 

 

Short Circuit

 

 

18-28

 

 

 

 

 

AUXILIARY POWER OUTPUT

120 Volt Receptacles

 

Open Circuit

240 Volt Receptacle

Load Amps

Open Circuit

Load Amps

Load Volts

 

Load Volts

Voltage

216-240

 

40-45

Voltage

 

115-130

18-22

240-270*

 

120-135

 

* Upper limit reflects cold machine, voltage will be below 132/264 for machine at normal operating temperature.

Open Circuit Voltage

42 VOLT WIRE FEEDER POWER

Load Amps

 

Load Volts

 

42-46

 

40-44

 

 

7.0-9.0

 

RANGER 305D

Page 156
Image 156
Lincoln Electric SVM175-A service manual Retest After Repair, Auxiliary Power Output