116 Call Forward Busy
Hunting
When a telephone is busy, an incoming call hunts only if Hunting is allowed
for that telephone. If all the steps in the hunt group are busy, and Call
Waiting is not allowed, the call forwards to the attendant console.
ICP Network Screen Activation, Flexible DN, Meridian Mail Interactions
When a call redirected by Call Forward All Calls, Call Forward No Answer,
Call Forward Busy, or Hunt terminates on an Intercept Computer (ICP)
position, a redirected message identification "50" is sent to the ICP
computer, when the call is answered.
Incoming Call Indicator Enhancement
When a DID call to station that is unrestricted from receiving DID calls (UDI
Class of Service) is forwarded to a UDI station due to Call Forward All Calls
or Call Forward Busy, the call is RDI-intercepted to the attendant. The
attendant display shows the DN of the dialed party.
If the call has been forwarded to the attendant, the Call Forward All
Calls/Call Forward Busy ICI lights up, and not the RDI-intercept ICI.
Lockout, DID Second Degree Busy, and MFE Signaling Treatments
Call Forward Busy takes precedence over lockout and second degree busy.
Network Intercom
Hot Type I calls respect or override all kinds of Call Forward features (Busy,
No Answer, All Calls, Internal, etc.) according to per-set definitions. If Call
Forward is respected, the call becomes a normally dialed call and the
originator will receive the appropriate indication on their display.
Night Service
When the system is in Night Service, DID calls forwarded by Call Forward
Busy are routed to the specified night number. If the night telephone is busy,
subsequent calls receive busy tone.
Recorded Announcement for Call Diverted to External Trunks
Recorded Announcement for Calls Diverted to External Trunks (RANX) is
activated if the call is forwarded to an outgoing external CO trunk with the
RANX feature active.
Recovery on Misoperation of Attendant Console
Call Forward takes precedence over the Misoperation feature.
Total Redirection Count
Call Forward Busy redirections is limited to the value defined in the Total
Redirection Count limit (if greater than 0). If this limit is exceeded, intercept
treatment is given.
Nortel Communication Server 1000
Features and Services Fundamentals — Book 2 of 6 (C)
NN43001-106 02.04 Standard
Release 5.5 9 May 2008
Copyright © 1994–2008, Nortel Networks
.