Feature operation 577
Feature implementation
Task summary list

The following is a summary of the tasks in this section:

1. "LD 15 - Configure the Console Presentation feature." (page 577)

Configure the Console Presentation feature.

2. "LD 15 - Configure the Queue Thermometer feature." (page 577)

Configure the Queue Thermometer feature.

Console Presentation
LD 15 - Configure the Console Presentation feature.
Prompt Response Description
REQ: NEW CHG Add, or change.
TYPE: ATT_DATA Attendant console options
...
- OPT (PSD) PSA Presentation Status selection allowed (denied) on attendant
consoles.
(CUI) MTI ICI lamps show Multi-tenant Service (MTS) Attendant
Console Group (AGP) information for incoming calls.
(RECO) RECA Attendant calls is redirected when there is no presentation
status to other consoles in the console group; RECO when
all consoles are busy, RECA when all but one console is
busy.
(NCD) NCA When an Attendant Console Group is in Night Service,
redirection of attendant calls is allowed (denied).

Queue Thermometer

LD 15 - Configure the Queue Thermometer feature.
Prompt Response Description
REQ: NEW CHG Add, or change.
TYPE: CDB Customer Data Block.
...
- OPT (DRE) DRT Queue thermometer includes (excludes) Inter-Attendant
calls, Recalls and Metered calls.
Feature operation
No specific operating procedures are required to use this feature.
Nortel Communication Server 1000
Features and Services Fundamentals — Book 2 of 6 (C)
NN43001-106 02.04 Standard
Release 5.5 9 May 2008
Copyright © 1994–2008, Nortel Networks
.