Feature implementation 519
Feature implementation
Task summary list
The following is a summary of the tasks in this section:
1. "LD 15 - Configure the CLASS CLID parameters in the Customer Data
Block." (page 519)
Configure the CLASS CLID parameters in the Customer Data Block.
2. "LD 10 - Configure the CLASS Calling Name and Calling Number
Delivery Class of Service for Analog (50" (page 520)
Configure the CLASS Calling Name and Calling Number Delivery Class
of Service for Analog (500/2500 type) sets.
3. "LD 13 - Configure the CLASS modem unit (up to 255 CLASS modem
units may be configured per system)." (page 521)
Configure the CLASS modem unit (up to 255 CLASS modem units may
be configured per system).
LD 15 - Configure the CLASS CLID parameters in the Customer Data Block.
Prompt Response Description
REQ: CHG Change or delete existing data.
TYPE: NET Networking data.
CUST Customer number
0-99 Range for Large System and CS 1000E system.
0-31 Range for Small System and Media Gateway 1000B.
...
CLID CLID option.
(NO) NO = (the default) do not configure a CLID table. In this case,
the remaining prompts are not generated, and no CLID is sent
for the customer.
YES YES = configure a CLID table for the customer.
- SIZE 0-(256)-4000 Number of CLID entries required.
...
Nortel Communication Server 1000
Features and Services Fundamentals — Book 2 of 6 (C)
NN43001-106 02.04 Standard
Release 5.5 9 May 2008
Copyright © 1994–2008, Nortel Networks
.