Feature implementation 557
LD 56 - Configure Conference Warning Tone
Prompt Response Description
REQ CHG Modify existing data.
TYPE FTC Flexible Tones and Cadences data block.
TABL 0FTC table number 0. Only table number 0 can be used to
make changes to the Conference Warning Tone.
...
RING NO Modify the ringing feature definitions.
HCCT YES Modification of the hardware controlled cadence tone
definitions allowed.
...
- EEST NO End-to-end Signaling type.
- CFWT Conference Warning Tone.
- - XTON 0-(3)-255 The Conference Warning Tone number. A tone number
provided by the tone circuit.
- - XCAD 0-(19)-255 The Conference Warning Tone cadence number. Cadence
number must have been previously set up within LD 56 by
responding to the TYPE prompt with FCAD.
LD 97 - Enable Conference Warning Tone
Prompt Response Description
REQ CHG Modify existing data.
TYPE XCTP Conference/TDS/MF Sender card parameters.
CPAD (0)
1
Conference pad values.
Use software pad values.
Use pad values defined by switch settings.
DTMF 0-(14)-255 Tone table of the first Dual-tone Multifrequency digit to be
used.
CFWT (NO) YES (Disable) enable Conference Warning Tone.
Note: For CS 1000E Release 5.0 and later, LD 34 must be
used to Enable/Disable Conference Warning Tone.
LD 34 - Enable Conference Warning Tone
Command Description
ENLX l Enable Conf/TDS/MFS card on loop l and l + 1.
DISX l Disable Conf/TDS/MFS card on loop l and l + 1.
Nortel Communication Server 1000
Features and Services Fundamentals — Book 2 of 6 (C)
NN43001-106 02.04 Standard
Release 5.5 9 May 2008
Copyright © 1994–2008, Nortel Networks
.