Feature implementation 463
Prompt Response Description
- ANIE (0)-N ANI Entry: it is of (0)-N where N=S_SIZE in customer data block.
If ANIE=0, no entry is associated with the set. The old
mechanism is used for building the ANI message.
If ANIE is of 1-N:
If ANIC = YES for the outgoing CIS route where the call
takes place, then the components of the ANI message are
retrieved from the ANI entry in Customer Data Block, if
configured.
If the given ANI Entry is not configured, or if ANIC = NO for
the outgoing CIS route where the call takes place, then the
old mechanism is used for building the ANI message.
... ... ...
LD 10 - Configure the CAC for CIS and MFC signaling for analog 500/2500 sets.
Prompt Response Description
REQ: NEW
CHG Add new data.
Change existing data.
TYPE: 500 Type of data block for analog (500/2500) set.
TN Terminal number
l s c u Format for Large System and CS 1000E system, where l = loop,
s = shelf, c = card, u = unit.
cu Format for Small System and Media Gateway 1000B where c =
card and u = unit.
CUST xx Customer number, as defined in LD 15
... ...
SFLT a..a Secretarial Filtering.
CAC_CIS 0-(3)-9 CIS ANI Category Code.
CAC_MFC (0)-10 MFC CNI Category Code.
LD 11 - Configure ANI entry for Meridian 1 proprietary sets.
Prompt Response Description
REQ: NEW
CHG
Add new data.
Change existing data.
TYPE: a...a Telephone type. Type ?for a list of possible responses.
Nortel Communication Server 1000
Features and Services Fundamentals — Book 2 of 6 (C)
NN43001-106 02.04 Standard
Release 5.5 9 May 2008