556 Conference Warning Tone Enhancement
for the Conference Warning Tone can be programmed to be distinctively
different from the tone and cadence produced by the Intrusion Tone given
by such features as Barge-In, Break-In, or Busy Verify.
Operating parameters
This feature only applies to the Cabinet system.
The Conference Warning Tone will only be contained and defined within
FTC Table 0. All other FTC tables will not contain any references to the
Conference Warning Tone and this tone cannot be copied to any other FTC
table by a numbered response to the DFLT (Default to existing FTC tone
table) prompt in LD 56. Since existing code does not allow FTC table 0 to
be deleted, there is no danger of deleting the Conference Warning Tone.
For cadence tables, table numbers above 15 should be chosen for the
Conference Warning Tone, because cadence tables numbers below 15 are
influenced by Software Controlled table numbers.
Feature Interactions

Tones and Cadences

There are no changes to the limitations to cadence numbers entry values.
The same restriction still applies.
Feature packaging
This feature is included in base system software.
Feature implementation
Note: When upgrading from a CS 1000S to a CS 1000E in Release 5.0,
if CFWT in LD 56 has a value other than 0, then conference warning
tones is enabled following the upgrade. After the upgrade, the CFWT
prompt is not available in LD 97. The conference warning tone must be
enabled/disabled and configured in LD 56.
Task summary list
The following is a summary of the tasks in this section:
"LD 56 - Configure Conference Warning Tone" (page 557)
Configure Conference Warning Tone.
"LD 97 - Enable Conference Warning Tone" (page 557)
Enable Conference Warning Tone.
"LD 34 - Enable Conference Warning Tone" (page 557)
Enable Conference Warning Tone.
Nortel Communication Server 1000
Features and Services Fundamentals — Book 2 of 6 (C)
NN43001-106 02.04 Standard
Release 5.5 9 May 2008
Copyright © 1994–2008, Nortel Networks
.