308 Called Party Control on Internal Calls
LD 10 - Enable Malicious Call Trace on Analog (500/2500 type) sets.
Prompt Response Description
REQ: NEW
CHG Add new data.
Change existing data.
TYPE: 500 Analog Set Type.
TN Terminal number
l s c u Format for Large System and CS 1000E system,
where l = loop, s = shelf, c = card, u = unit.
cu Format for Small System and Media Gateway 1000B where c =
card and u = unit.
CUST xx Customer number, as defined in LD 15
...
CLS MCTA Malicious Call Trace allowed.
MCTD = Malicious Call Trace denied.
LD 11 - Enable Malicious Call Trace on Meridian 1 proprietary sets.
Prompt Response Description
REQ: NEW
CHG Add new data.
Change existing data.
TYPE: a...a Telephone type. Type ?for a list of possible responses.
TN Terminal number
l s c u Format for Large System and CS 1000E system,
where l = loop, s = shelf, c = card, u = unit.
cu Format for Small System and Media Gateway 1000B where c =
card and u = unit.
CUST xx Customer number, as defined in LD 15
...
CLS
KEY
MCTA
xxx TRC
Malicious Call Trace allowed.
MCTD = Malicious Call Trace denied.
Key Number, Malicious Call Trace.

For information on the implementation of the Malicious Call Trace feature,

refer to the Malicious Call Trace feature description in Features and Services

Fundamentals (NN43001-106), Book 2.

Feature operation

Feature operation is described in the following scenarios.

Nortel Communication Server 1000
Features and Services Fundamentals — Book 2 of 6 (C)
NN43001-106 02.04 Standard
Release 5.5 9 May 2008
Copyright © 1994–2008, Nortel Networks
.