Omega RD100B manual Turning Printouts ON/OFF, Pen model

Models: RD100B

1 234
Download 234 pages 60.28 Kb
Page 133
Image 133

7.7 Turning Printouts ON/OFF.

This section explains the details of turning ON/OFF the printouts of various items. Basic Setting mode cannot be entered when recording is in progress or when computation is in progress on models with the computation function (/M1 option).

Procedure

Changing the Settings

1.Hold down the MENU key for 3 seconds to enter Setting mode.

2.Hold down the and keys simultaneously for 3 seconds to enter Basic Setting mode.

3.Press the key or SHIFT + key to select Print and then press the key.

4.Set each item and press the key.

Use the key or SHIFT + key to select values.

For the procedure on how to enter values or characters, see section 4.2.

If you press the ESC key in the middle of the operation, the settings entered up to then are cancelled, and the display returns to a higher level menu.

5.When the Setting complete screen appears, do either of the following:

To correct the setting, press the key. If you are done, press the ESC key.

Basic=Print

CH/Tag=Channel

(Dot model)

Channel=On

Alarm=On1

Record On=Off

Chart speed=On

Scale=On

(Pen model)

Pen color=On

Printout

ESC/? Setting complete

Select whether to use the channel number or tags for the printout.

Select whether to print the channel number beside the trend recording.

Select whether to print the alarm occurrence/release.

Select On to enable recording start printout.

Prints when the chart speed is changed.

Select On to print the channel scale in periodic printout.

Select On to print the pen color in periodic printout.

The new setting takes effect.