4.4 Function Setup Guide

Display functions

Item

Description

Reference

 

 

 

Section

 

 

 

Display brightness

Use Aux > Brightness > Display in Setting mode to set the display brightness.

6.11

 

 

 

Bar graph display mode

Use Bar graph in Basic Setting mode to set the bar graph display mode.

7.9

 

 

 

Display type

Assigns the display type on the data display setup screen.

Chapter 8

 

 

 

Date format

Same as the Date format in “Recording functions.”

7.19

 

 

 

 

Other functions

 

 

 

 

 

 

Item

Description

Reference

 

 

 

Section

 

 

 

Key lock

• Target keys and password

7.10

 

Use Keylock in Basic Setting mode to set the keys to be key-locked and the

 

 

password.

 

 

• Enable the key lock

3.13

 

Use FUNC key > Keylock in Operation mode to turn key lock ON/OFF.

 

 

 

 

Language

Use Language in Basic Setting mode to set the display and recording language.

7.14

 

 

 

Internal light brightness

Use Aux > Brightness > Light in Setting mode to set the internal light brightness.

6.11

 

 

Computation function (/M1 option)

 

 

 

 

Item

Description

Reference

 

 

 

Section

 

 

Computing equation and recording span

 

 

Use Math > Formula in Setting mode to set the computing equation and

9.2

 

recording span for each channel.

 

 

 

 

TLOG computation

If TLOG computation is selected, use Math > Timer in Basic Setting mode to

9.12

 

set the timer operation

 

 

Use Math > TLOG > Timer No. in Setting mode to set the timer used on each

9.6

 

computation channel.

 

 

 

 

Unit

Use Math > Unit in Setting mode to set the unit for each channel.

9.3

 

 

 

Constants

Use Math > Constant in Setting mode to define constants to be used in the

 

 

computing equations.

9.4

 

 

 

Alarms

Use Math > Alarm in Setting mode to set the alarm for each channel.

9.5

 

• Delay high limit alarm/delay low limit alarm

 

 

Alarm type

7.15

 

 

Use Personalize > Add function > Alarm delay in Basic Mode and select

 

 

 

Use or Not (common with measurement channels).

 

 

 

If Use is selected, delay high limit alarm and delay low limit alarm become

 

 

 

selectable under Math > Alarm > Type in Setting mode. If Not is selected,

 

 

 

alarm delay cannot be selected.

 

 

Alarm delay time

9.11

 

 

Use Math > Aux > Alm delay T in Setting mode to set the alarm delay time.

 

 

 

Record by setting recording zone for each channel

 

 

Use Math > Aux > Zone in Setting mode to set the recording zone for each channel.

9.7

 

 

Partial expanded recording Use Partial in Basic Setting mode and select Use or Not.

7.13

 

If Use is selected, set the display mode using Math > Aux > Partial in Setting mode. 9.8

 

If Not is selected, the Math > Aux > Partial item does not appear.

 

 

 

Change the recording color (dot model)

 

 

Use Color in Basic Setting mode to set the recording color of each computation

9.13

 

channel.

 

 

 

Recording pen assignment (pen model)

 

 

Assigns measurement/computation channels to the recording pens.

9.14

 

 

Turn trend recording ON/OFF (dot model)

 

 

Use Math > Aux > Print out > Trend in Setting mode to set whether to trend record

9.9

 

each computation channel.

 

 

 

 

 

4-16

Page 93
Image 93