Omega RD100B manual Channel data, alarm, scale printout, and chart speed, Scale and chart speed

Models: RD100B

1 234
Download 234 pages 60.28 Kb
Page 226
Image 226

Appendix 1 Periodic Printout and Printout Using the TLOG Timer (/M1 Option)

Dot Model

Instantaneous Mode

 

 

Channel No.

Measured

 

 

or tag

 

value

 

 

 

 

Unit

Date

 

Mar.31.2004

 

 

Time

 

15:50

 

 

 

 

 

Channel data

 

TAG-001

1.000V

 

2-1.000V

3H-2.1050UNIT03

4d 2.000V

Computation channel

 

TAG-00A

 

1UNIT0A

 

J

L

-1.00UNIT0J

 

 

Scale

 

0.000

 

 

 

TAG-001

 

 

Chart speed

 

 

 

 

50mm/h_

 

 

 

 

 

Prints the letter “d” for channels set to delta computation.

2.000 V

Time tick

Alarm

Date/Time

The date/time when the periodic printout was executed.

Time tick

Indicates the position at the time the periodic printout was executed. If the time tick cannot be printed correctly, it is not printed.

Channel data, alarm, scale printout, and chart speed

These are the same as with the instantaneous mode of the pen model.

Report Mode

 

 

 

Channel No. or tag

Event

 

 

 

 

Range change occurrence mark

Sum value

 

 

 

 

Measured value

Min./Max./Ave.

 

 

 

 

Unit

 

 

Report start date/time

Mar.31.2004 15:00

 

 

Report end date/time

 

 

-Apr.01.2004 15:00*TPR

 

 

 

 

 

Channel data

 

 

TAG-001*1.000V

 

 

 

 

 

 

 

 

2

-1.000V

 

 

 

 

 

3

-2.105500E+03UNIT03

 

 

 

 

 

4

2.000V

 

 

 

 

 

TAG-00A 1UNIT0A

 

 

 

 

 

C

*1.00

 

 

 

 

 

D

-10.00UNIT0D

 

 

Computation channel

 

150.00UNIT0D

 

,

 

 

 

 

100.00UNIT0D

 

 

 

 

E

1.0000%

 

 

 

 

 

J

-1.00UNIT0J

 

 

Scale

 

 

0.000

 

2.000

 

 

 

TAG-001

 

V

 

Chart speed

 

 

 

 

 

 

50mm/h_

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Time tick

Report start date/time and report end date/time

The start date/time and end date time of the report (statistical calculation) (periodic printout interval).

Time tick

This is the same as with the instantaneous mode.

Event

This is the same as with the report mode of the pen model.

Channel data

This is the same as with the report mode of the pen model. However, the channel numbers are 1 to 6 or A to P.

Scale and chart speed

These are the same as with the instantaneous mode of the pen model.

App-3

Periodic Printout

and Printout Using the TLOG Timer (/M1 Option)

App

Page 226
Image 226
Omega RD100B manual Channel data, alarm, scale printout, and chart speed, Scale and chart speed