User’s Guide
 For immediate technical or application assistance
 Revisions
Foreword
Trademarks
Electronic Manuals Provided on the Accompanying CD-ROM
 Software Sold Separately
Recorder’s Version and Functions Described in This Manual
RD100B Versions and Functions
Version Suffix Code Added or Modified Functions Reference
 About This Manual
Safety Precautions
Safety Standards and EMC Standards
Iii
 Handling Precautions of the Software
Exemption from Responsibility
 Checking the Contents of the Package
 Optional Accessories Sold Separately
Standard Accessories
Checking the Contents of the Package
 Dot Model
Removing the Packing Materials
Pen Model
Vii
 How to Use This Manual
Viii
 Conventions Used in This Manual
 Contents
 Setup Operations for Convenient Functions Setting Mode
Contents
 Maintenance
Xii
 Overview of the Recorder
 Measuring Input Section
Input Section
 Scaling
Measuring Input Section Delta Computation
Square Root Computation
 Reference Junction Compensation of Thermocouple Input
Burnout Detection of Thermocouples
Measuring Input Section Bias
 Filter and Moving Average
Noise Elimination from Input Signals
Measuring Input Section
Filter Pen Model
 Integration Time of the A/D Converter
Model Integration Time of the A/D Converter
 Alarms
Alarm Types
 Delay High Limit Alarm Example T is the specified delay
Alarms Delay High Limit Alarm T
Delay Low Limit Alarm t
Alarm Hysteresis
 Alarm Output Relay /A1, /A2, and /A3 Options
Alarm Indication
Alarm Recording
Non-Hold/Hold Operation of the Alarm Indication
 Alarm
Alarms Reflash Alarm
Channel Approx ms Approx ms
 Functional
Alarms AND/OR Operation of Alarm Output Relays
Energized/De-energized Operation of Alarm Output Relays
Description
 Alarm ACK Operation
Alarms Non-Hold/Hold Operation of Alarm Output Relays
 Recording
 Recording Method Pen Model
Chart Speed
Trend Recording
Recording Method Dot Model
 Compressed Expanded
Recording Partial Expanded Recording
Pen Offset Compensation Pen Model
Same time
 Printout
Printout Example on the Pen Model
 Recording Printout Example on the Dot Model
Functional Description Channel Printout Dot Model Only
 Periodic Printout
Recording Alarm Printout
Printout Contents for details, see appendix
Interval
 Manual Printout
New Chart Speed Printout
Recording Turning ON/OFF the Periodic Printout
Message Printout
 Recording Setting Printout
Printout Example of List on the Pen Model
 Printout Example of List on the Dot Model
 Displayed Information
Display
Display Types
 Channel Digital + 1 Bar Graph Display
Alarm Status Display
Date/Time and Chart Speed
Flag Display
 Channels Dedicated to Computations
Computation Function /M1 Option
Computation Function
Types of Computations
 Trend Recording
Handing of the Unit in Computations
Recording Computation Channels
Assignment of Computation Channels to the Pens Pen Model
 Starting/Stopping Computation
Alarms
Display
Printout
 Fail Output
FAIL/Chart End Detection and Output Function /F1 Option
Chart End Output
Fail Relay Output
 Remote Control Function /R1 Option
 Remote Signal Edge, Trigger, and Level
Remote Control Function /R1 Option Computation Start/Stop
Computation Reset
Rising/Falling edge Trigger Level Ms or more
 Key Lock
Temperature Unit
Other Functions
Language
 Handling Precautions
Handling Precautions
Before Using the Recorder
 Installation
Installation Location
 Front Contact With each other
Installation Procedure
Installation
Flat blade
 External Dimensions of the Recorder
Panel Cutout
 General Precautions to Be Taken While Wiring
Input Signal Wiring
Precautions to Be Taken While Wiring
 Screw input terminal
Arrangement of the Measuring Input Terminals
Measuring input terminal block
Clamped input terminal H2 option
 Before Using
Input Signal Wiring Dot Model
Recorder
 Input Signal Wiring
Measuring Input Wiring
DC current input +/A Shunt resistor
 Crimp-on lug with insulation sleeves for 4 mm screws
Optional Terminal Wiring
Arrangement of the Optional Terminals
Optional terminal block
 Optional Terminal Wiring
Remote Control Input Terminals
 Relay Contact Input/Transistor Input Specifications
Wiring Procedure
Relay Contact Output Specifications
Relay contact output Voltage-free contact Open collector
 Precautions to Be Taken While Wiring the Power Supply
Power Supply Wiring
Power Supply Specifications
 Power Supply Wiring
 Turning ON/OFF the Power Switch
Checking the Date/Time
 Names of Parts and Run Operations
Names of Parts
Front
Names of Parts
 Seven keys are available
Display and Key Panel
Status display
During normal operation CH UP key
 Rear Panel
Names Parts Run Operations
 Loading the Chart Paper
Installing or Replacing the Chart Paper
Stopper
 Chart holder
Installing or Replacing the Chart Paper
Fold chart paper Sprocket teeth
Side with
 Feeding the Chart Paper
 Replacing Felt Pens
Installing/Replacing Felt Pens or Plotter Pen Pen Model
Display and key panel
 Replacing the Plotter Pen
 Installing/Replacing the Ribbon Cassette Dot Model
Holder tab
 Cassette holder
Installing/Replacing the Ribbon Cassette Dot Model
Hole for the ribbon Feed shaft Ribbon feeding knob
 Starting the Recording
Recorded chart paper can be pulled out Front cover tab
Starting/Stopping the Recording
Stopping the Recording
 Channel Auto Switching
Switching the Display Screen
Switching the Display Screen
Switching the Displayed Channel Using Keys
 Starting the Manual Printout
Printing Measured Values Manual Printout
Aborting the Manual Printout
 Aborting the Setup Printout
Printing the Recorder Settings
Starting the Setup Printout
Starting the List Printout
 Clearing the Alarm Printout Buffer
Buf.clear=Alarm
 Printing a Message
Displays the preset message
Printing Messages
Clearing the Message Printout Buffer
 Resetting the Report Data of the Periodic Printout
Resetting the Report Data
 Alarm Output Relay Operation
Releasing the Alarm Output Alarm ACK Operation
Releasing the Alarm Output
Alarm Alarm output relay Blinking Alarm indication
 Activating the Key Lock
Activating/Releasing the Key Lock
Releasing the Key Lock
 Run Modes
 Exiting from Setting Mode Returning to Operation Mode
Entering Setting Mode
Entering Basic Setting Mode
Exiting from Basic Setting Mode Returning to Operation Mode
 Entering Values
Changing the Settings
Using the ESC Key
Key Operations
 Deleting a Character
Entering Characters
Inserting Characters
Copying & Pasting a Character String
 Menu Structure, Settings, and List of Default Values
Operation Menus Using the Func Key Operation Mode
 Exchange Dot Model
 Menu Structure of Setting Mode
Menu Structure, Settings, and List of Default Values
 Menu Structure of Basic Setting Mode
POC
 Setup Items in Setting Mode and Their Default Values
 Setup Items in Basic Setting Mode and Their Default Values
RJC RJC
 Setting initialization
Remote control function /R1 option
 NORMAL/MODBUS Normal
 Function Setup Guide
Description Reference Section
 Alarm functions Description Reference Section
Function Setup Guide
Recording functions Description Reference Section
 Or tag
Channel number
Recording color
 Display functions Description Reference Section
Other functions Description Reference Section
 Timer number
Computed value
 Frequently Used Setup Operations Setting Mode
Setting the Input Range
TC, RTD, and DC Voltage
 N1 Option
Setting the Input range
Selectable Range of Input Range, Span Left, and Span Right
Input Type
 Linear Scaling
 Span Left and Span Right
Delta Computation
First channel Last channel
 ON/OFF Input
Range Type Selectable Span Values
 Low-cut
5V Input
Scale Left and Scale Right
Select the right scale value
 Low-cut and Low-cut Point
Square Root Computation
To 5.0% of the recording span, 0.1 steps
 Set the channel range Select Skip New setting takes effect
Skip Unused Channels
 Setting the Alarm
 Symbol Name
Setting the Alarm
Alarm Type
Channel Range
 Difference High Limit Alarm/Difference Low Limit Alarm
Relay No
 Setting the Unit on Scaled Channels
 Chart speed on the pen model unit mm/h
Changing the Chart Speed
Mode
 Date/Time New setting takes effect
Setting the Date/Time
Recorders with Version 1.02 or Earlier
 Functions Setting Mode
Setting the Trend Recording Interval Dot Model
Setup Operations for Convenient Functions Setting Mode
When set to Auto
 Setting the Filter Pen Model
Filter Time Constant
 New setting takes effect
Setting the Moving Average Dot Model
Number of Samples of Moving Average
 Setting Recording Zones for Each Channel Zone Recording
Zone
 Setting the Partial Expanded Recording
Expand
 Trend Recording Dot Model
 Setting Tags on Channels
Characters That Can Be Used for Tags
 Setting the Message String
Characters That Can Be Used for Messages
 See section
 Setting the Alarm Delay Duration
Duration New setting takes effect
 Display Brightness
Setting the Brightness of the Display and Internal Light
Internal Light Brightness
 Applying a Bias on the Measuring Input Signal
When bias is On
 Setup Operations For Convenient Functions Setting Mode
 Start month, Strt day, and Start time
End month, End day, and End time
 DST
 Changing the Auxiliary Alarm Function
Changing the Settings
 Changing the Auxiliary Alarm Function
Diagnosis
 Act
Changing the Auxiliary Alarm Function Reflash
Indicator
Behavior
 Changing the Integration Time of the A/D Converter
Integrate
 Setting the Burnout Detection Function of Thermocouples
Burnout
 Setting the RJC Function on Channels Set to TC Input
 Setting the RJC Function on Channels Set to TC Input
Volt
 Changing the Channel Recording Color Dot Model
Color
 POC Pen Offset Compensation
 Turning Printouts ON/OFF
Pen model
 Channel Dot Model
Alarm
CH/Tag
Pen Color Printout
 Periodic Printout Interval
 Changing/Adding Functions Basic Setting Mode
Types of Report Data to Be Printed
 Ref. Time
SUM scale
 Functions Basic Setting Mode
Setting the Bar Graph Display Mode
Setup
Graph
 Setting the Key Lock Function
 Setting the Key Lock Function
 Password
Operation of Keys to Be Key-Locked
 Enabling the Moving Average Function Dot Model
MovingAVE
 Enabling the Filter Function Pen Model
Filter
 Enabling the Partial Expanded Recording Function
Partial
 Changing the Display/Recording Language
Lang Language
 Procedure
 Sqrt low-cut
Alarm delay
5V low-cut
 Changing the Time Printout Format
 RCD On
Changing the Time Printout Format
Speed
 Basic=Initialize screen
Initializing the Settings
ESC/?
 Changing the Settings
 Remote No
Function to Be Assigned
 Changing the Printout/Display Format of the Date
Setting Format Example
Date Format
 Changing the Temperature Unit
Temp Temperature
 Setup Operations for Changing Displayed Contents
Setup Operations for Changing the Displayed Contents
Displaying the Data Display Setup Screen
Key Operations for Changing the Displayed Information
 End
Data Display Setup Menu
Key Operations for Changing the Displayed Information
End Flag display
 Channel Digital Display
Changing the Displayed Contents
Changing the Displayed Information
Assigning Other Display Types See the menu on the previous
 Starting the Computation
Starting/Stopping/Resetting the Computation
Operations Related to the Computation Function /M1 Option
Stopping the Computation
 Setting the Computing Equation
 Inserting a Character
Description Character Key
 Order of Precedence in Computations
Computing Equation
Type Operator
 Four Arithmetic Operation
Power and Other Computations
Equation Examples
 Relational Computation
Logical Computation
 XOR
Equation Example 01-02OR03.GT.04
 Equation Example
Tlog Computation
Examples of Equations That Are Not Allowed
 Setting the Unit
Characters That Can Be Used for Units
 Setting the Constants Used in Equations
Constant
 Select On to set the alarm. When set
 Alarm Value
 Specifying the Timer Used in Statistical Calculations Tlog
 Timer operation
Specifying the Timer Used in Statistical Calculations Tlog
Timer No
Timer # Periodic
 Set the leftmost value of the recording
 New setting takes effect Related Topics
 Dot model
 Set= Math Math= Aux Aux= Tag
 Duration
 Basic=Math Math=TimerTLOG Timer No.=1 Mode=Absolute
 Timer Type
Timers
Number of Timers
Absolute Time Mode
 Timer timeout Reset Reset Reset Reset On Reset Off
Example TLOG.SUM computation
 Select the channel
 Changing the Channel Assignments of Recording Pens Pen Model
Output pen
 Operations
Function /M1 Option
 Setting the periodic printout interval Section
 Select the display mode of the bar
 Select the computation error procedure
 Over
Error
Channel Limit Value
 Troubleshooting
List of Error Messages
Setting Errors
Troubleshooting 10-1
 List of Error Messages
Operation Errors
Communication Errors
When the timer expired
 System Errors
Troubleshooting 10-3
 Troubleshooting Flow Charts
10-4
 Troubleshooting Flow Charts
10-5
 10-6
 Remaining amount of chart paper
Maintenance
Maintenance 11-1
Periodic Inspection
 Pen Model
Cleaning the Recorder
Cleaning Procedure
Dot Model
 Flexible printed circuit board LED assembly Connector
Replacement Procedure
Maintenance 11-3
Replacing the Internal Light LED
 Calibrating the Recorder
Calibration Procedure
Required Instruments
 Maintenance 11-5
Temperature Measurement When Using a Thermocouple
RJC of TC input
 Basic=PAdj screen
Adjusting the Pen Position Pen Model
11-6
 Adjusting Zero and Full
Adjusting the Dot Printing Position Dot Model
Adjusting the Hysteresis
Maintenance 11-7
 Adjusting the Dot Printing Position Dot Model
11-8
 Maintenance 11-9
Recommended Replacement Periods for Worn Parts
Part Name Quantity Period Used
 Replacement Part Name Quantity Period Used
Recommended Replacement Periods for Worn Parts Dot Model
11-10
 Number of Inputs and Scan Interval on the Dot Model
Input Specifications
Number of Inputs and Scan Interval on the Pen Model
Input Type
 12-2
Input Specifications
Input Computation Standard Function
Input Type Operating Conditions
 Alarm Function Specifications
Specifications 12-3
 Trend Recording Pen Model
Recording Function Specifications
Chart Paper
Trend Recording Dot Model
 Specifications 12-5
Recording Function Specifications
Printouts Pen Model
 Printout Dot Model
12-6
 Display Function Specifications
Display and Displayed Contents
 12-8
Display Function Specifications
ItemSpecifications
Status Display Description
 Specifications 12-9
Symbol Description
 12-10
 Channel digital display Measurement channel Tag display
Specifications 12-11
Name Display Example DI/DO status display Status display
Digital display is the same as
 12-12
 Specifications 12-13
Specifications of Optional Functions
Alarm Output Relay /A1, /A2, and /A3
RS-422A/485 Communication Interface /C3
 Non-Glare Door Glass /H3
FAIL/Chart End Detection and Output /F1
Clamped Input Terminal /H2
Computation Function /M1
 Legs Isolated RTD /N2
Specifications 12-15
Cu10, Cu25 RTD Input /N1
Expansion Inputs /N3
 Time When Signal Is Input Procedure
Remote Control 5 Points /R1
12-16
 Specifications 12-17
General Specifications
Power Supply
Construction
 Transport and Storage Conditions
General Specifications
Isolation
Supported Standards
 Standard Performance
Specifications 12-19
Resolution
Excludes
 Effects of Operating Conditions
Other Specifications
12-20
 220
Dimensional Drawings
Specifications 12-21
144 151.5
 Periodic Printout
 Scale, recording color, and chart speed
Report Mode
Time tick and time tick cancel mark
Recording color
 Channel data, alarm, scale printout, and chart speed
Scale and chart speed
 Offset compensation mark, scale, and recording color
Printout Using the Tlog Timer /M1 Option
Timer
App-4
 Time of Recovery Statistical Calculation Operation
Operation during Power Failures
Procedure of Handling Over Values during Periodic Printout
Special Cases
 Index
Index Index-1
 Index
Index-2
 Index Index-3
7-11
 Index-4
 WARRANTY/DISCLAIMER
 Shop online at omega.com