4.3 Menu Structure, Settings, and List of Default Values

Setup Items in Setting Mode and Their Default Values

Items with an asterisk on the left are not displayed in the default condition. To display

these items, settings must be changed in Basic Setting mode.

Setup Item

Pen/Dot

Selectable Range or Selections

Default Value

Range > CH

-

01 to 06

01

Range > Mode

-

Volt/TC/RTD/1-5V/Scale

Volt

 

 

/Delta/DI/SQRT/Skip

 

Range > Mode > Range

-

20mV/60mV/200mV/2V/6V/20V/50V/1-5V

2V

 

 

/R/S/B/K/E/J/T/N/W/L/U/WRe/Pt/JPt/Level/Cont

 

 

 

/(Slections for /N1 and /N3 options)

 

 

 

 

 

*Bias > CH

-

01 to 06

01

*Bias > Bias

-

On/Off

Off

*Bias > Bias

-

±10 % of the span of the measurable range

-

 

 

 

 

Alarm > CH

-

01 to 06

01

Alarm > Level

-

1/2/3/4

1

Alarm > Alarm

-

On/Off

Off

Alarm > Type

-

H/L/h/l/R/r (*/T/t)

H

Alarm > Value

-

Depends on the alarm type.

-

Alarm > Relay

-

On/Off

Off

Alarm > Relay No.

-

I01 to I06

I01

 

 

 

 

Unit > CH

-

01 to 06

01

Unit > Unit

-

6 characters or less

Blank

 

 

 

 

Chart

Pen Model

82 types (pen model)

20 mm/h

 

Dot Model

1 to 1500 mm/h (dot model)

20 mm/h

 

 

 

 

Clock

-

Date/Time

-

 

 

 

 

Aux > Trend

Dot Model

Auto/Fix

Auto

Aux > Zone > CH

-

01 to 06

01

Aux > Zone > Left, Right

-

Within the recording span range (mm)

Left: 0, Right: 100

*Aux > Partial > CH

-

01 to 06

01

*Aux > Partial > Partial

-

On/Off

Off

*Aux > Partial > Expand

-

1 to 99%

50

*Aux > Partial > Boundary

-

Within the recording span range

-

Aux > Print out > CH

-

01 to 06

01

Aux > Print out > Trend

Dot Model

On/Off

On

Aux > Print out > Periodic

-

On/Off

On

Aux > Tag > CH

-

01 to 06

01

Aux > Tag > Tag

-

7 characters or less

1 to 6

Aux > Message > Message No.

-

1 to 5

1

Aux > Message > (Message)

-

16 characters or less

Blank

Aux > Chart2

Pen Model

82 types (pen model)

20 mm/h

 

Dot Model

1 to 1500 mm/h (dot model)

20 mm/h

*Aux > Moving_AVE > CH

Dot Model

01 to 06

01

*Aux > Moving_AVE > No. of samples

Dot Model

Off, 2 to 16

Off

*Aux > Filter > CH

Pen Model

01 to 06

01

*Aux > Filter > Resp. Time

Pen Model

2s/5s/10s

Off

*Aux > Alm delay T > CH

-

01 to 06

01

*Aux > Alm delay T > Duration

-

0 to 3600s

10s

Aux > Brightness > Display

-

1/2/3/4/5/6/7/8

4

Aux > Brightness > Light

-

1/2/3/4

2

Aux > DST

-

Not/Use

Not

Aux > DST > Start month

-

Apr/May/Jun/Jul/Aug/Sep/Oct/Nov/Dec/Jan/Feb/Mar

Apr

Aux > DST > Strt day

-

1st-Sun/.../Last-Mon

1st-Sun

Aux > DST > Start time

-

0:00 to 23:00

0:00

Aux > DST > End month

-

Apr/May/Jun/Jul/Aug/Sep/Oct/Nov/Dec/Jan/Feb/Mar

Apr

Aux > DST > End day

-

1st-Sun/.../Last-Mon

Last-Mon

Aux > DST > End time

-

0:00 to 23:00

0:00

 

 

 

 

Computation function (/M1 option)

 

 

 

 

 

 

 

Setup Item

Pen/Dot

Selectable Range or Selections

Default Value

 

 

 

 

Math > Formula > CH

-

0A/0B/0C/0D/0E/0F/0G/0J/0K/0M/0N/0P

0A

Math > Formula > Mode

-

On/Off

Off

Math > Formula > f.

-

120 characters or less

01

Math > Unit > CH

-

0A/0B/0C/0D/0E/0F/0G/0J/0K/0M/0N/0P

0A

 

 

 

 

4

Common Operations

for Setting Functions and

Setup Guide

4-9

Page 86
Image 86
Omega RD100B manual Setup Items in Setting Mode and Their Default Values