1.4 Recording

Trend Recording

The measured values are printed within a width of 100 mm.

Recording Method (Pen Model)

The measured value is updated every scan interval and continuously recorded.

The recording colors in order from channel 01 are red, green, blue, and violet.

Recording Method (Dot Model)

The most recent measured value is recorded with a dot every dot printing interval. The dot printing interval is in the range of 10 s to 90 s. There are two recording methods from which you can select. One method automatically adjusts the dot printing interval according to the chart speed so that the dots do not overlap. The other method records at the fastest dot printing interval at all times.

The recording colors in order from channel 01 are purple, red, green, blue, brown, and black. The recording color of each channel can be changed among these six colors.

For each channel, trend recording can be enabled or disabled.

<Related Topics>

Setting the dot printing interval: Section 6.1

Changing the recording color: Section 7.5

Enabling/Disabling trend recording for each channel: Section 6.6

Chart Speed

On the pen model, the chart speed can be selected from 82 settings in the range of 5 to 12000 mm/h.

On the dot model, the chart speed can be set in the range of 1 to 1500 mm/h in 1-mm steps.

The default setting is 20 mm/h.

<Related Topics>

Setting the chart speed: Section 5.4

Zone Recording

A recording zone is assigned to each channel.

Zone 1

Zone 2

Zone 3

<Related Topics>

Setting the zone recording: Section 6.4

1-14

Page 28
Image 28
Omega RD100B manual Trend Recording, Recording Method Pen Model, Recording Method Dot Model, Chart Speed, Zone Recording