Chapter 3 Selecting Output Jacks

Example of Settings

Assigning Different Output Destinations for the Tones in a Patch

In this example, let’s suppose we have a Patch composed of four Tones, and we are outputting Tone 1 from the A OUTPUT jacks, Tone 2 from the B OUTPUT jacks, Tone 3 from the INDIVIDUAL 5 jack, and Tone 4 from the INDIVIDUAL 6 jack. The Chorus and Reverb are output from the B OUTPUT jacks.

First, set the output destination for each Tone.

1.Select the Patch you wish to set.

2.Press [F6 (Effects)].

3.Press [F1 (General)] to call up the PATCH Effects General page.

4.Use TONE SELECT [1]–[4] to select the Tone you wish to set up.

5.Press [ ]/[ ]/[ ]/[ ] to move the cursor to the parameter you wish to set, and rotate the VALUE

dial, or press [INC] or [DEC] to set the value as follows.

 

 

Tone Output Tone Dry

Tone Chorus

Tone Reverb

 

 

Assign

Send Level

Send Level

Send Level

 

 

 

 

 

 

Tone 1

A

127

100

100

Tone 2

B

127

100

100

Tone 3

5

127

100

100

Tone 4

6

127

100

100

The Chorus and Reverb send levels can be set to any value you wish other than 0.

6.Press [EXIT] to return to the PATCH PLAY page.

7.Press [F1 (Common)].

8.Press [ ]/[ ] to move the cursor to Output Assign.

9.Turn the VALUE dial or press [INC]/[DEC] to select “TONE.”

10.Press [EXIT] to return to the PATCH PLAY page.

Next, select the Chorus output destination and set its overall level.

11.Press [F6 (Effects)].

12.Press [ ]/[ ]/[ ]/[ ] to move the cursor to Chorus Output Assign.

13.Turn the VALUE dial or press [INC]/[DEC] to select “B.”

14.Press [ ]/[ ]/[ ]/[ ] to move the cursor to Chorus Level.

15.Turn the VALUE dial to select “100.”

16.Press [ ]/[ ] to move the cursor to Chorus Output Select.

17.Turn the VALUE dial or press [INC]/[DEC] to select “MAIN.”

Finally, select the Reverb output destination and set its overall level.

18.Press [ ]/[ ]/[ ]/[ ] to move the cursor to Reverb Output Assign.

19.Turn the VALUE dial or press [INC]/[DEC] to select “B.”

20.Press [ ]/[ ]/[ ]/[ ] to move the cursor to Reverb Level.

21.Turn the VALUE dial to select “100.”

22.Press [EXIT] to return to the PATCH PLAY page.

110

Page 110
Image 110
Roland XV-5080 owner manual Example of Settings, 110