Setting the Tuning and Volume Settings

Master

The Master Tune and Master Key Shift settings are common to all Patches, Performances, Rhythm Sets, and the GM Mode.

Level (Master Level)

Range: 0–127

Adjusts the volume of the entire XV-5080.

Tune (Master Tune)

Range: 415.3–466.2 kHz

Adjusts the overall tuning of the XV-5080. The setting is expressed as the frequency played by the A4 key.

Key Shift (Master Key Shift)

Range: -24– +24

Shifts the overall pitch of the XV-5080 in semitone steps.

*When a Multi-partial Patch or Rhythm Set is selected, this setting is disabled.

Setting the System Tempo

System Tempo

Clock Source (System Clock Source)

Specifies the tempo clock of the system.

Available Settings:

INT: The internal clock will be the tempo clock for the system.

MIDI: An external clock will be the tempo clock for the

system.

Tempo (System Tempo)

Range: 20–250

Sets the system tempo.

*When Clock Source is set to “MIDI,” the tempo will synchronize to the clock messages received from an external MIDI device, so the tempo value will be ignored.

Chapter 9 Other Settings/Status Checks

Making Scale Tune Settings ([SYSTEM/UTILITY] - [F1 (General)])

fig.09-002.e_70

Scale Tune

The XV-5080 allows you to use temperaments other than equal temperament. The pitch of each note can be adjusted in one-cent steps (1/100th of a semitone) relative to its equal- tempered pitch.

One set of Scale Tune settings can be created in Patch mode. In Performance mode and GM system mode, each Part can have its own Scale Tune settings.

*The selected scale applies to MIDI messages received from an external MIDI device as well as to local sound generation.

Switch (Scale Tune Switch)

Turn this on when you wish to use a tuning scale other than equal temperament.

Patch Scale C–B

Range: -64– +63

Key Scale C–B

Range: -64– +63

The Settings in Patch Mode (Patch Scale)

*The Patch’s scale tune settings share the same settings as those for Part 1 of the Performance.

1.Press [PATCH], getting its indicator to light.

2.Press [SYSTEM/UTILITY], and confirm that its indicator has lighted.

*If the indicator is blinking, you are in UTILITY mode. Press [SYSTEM/UTILITY] once again to get the indicator to light steadily.

3.Press [F1 (General)] several times to call up the SYSTEM General #2 page.

4.Press [ ]/[ ]/[ ]/[ ] to move the cursor to the note name you want to set.

Chap.9

209

Page 209
Image 209
Roland XV-5080 owner manual Making Scale Tune Settings SYSTEM/UTILITY F1 General, Setting the Tuning and Volume Settings