OMNI OFF (Controller number 124)

Status

2nd byte

3rd byte

BnH

7CH

00H

n = MIDI channel number:0H - FH (Ch.1 - 16)

*The same processing will be carried out as when All Notes Off is received.

MNI ON (Controller number 125)

Status

2nd byte

3rd byte

BnH

7DH

00H

n = MIDI channel number: 0H - FH (Ch.1 - 16)

*The same processing will be carried out as when All Notes Off is received. OMNI ON will not be turned on.

MONO (Controller number 126)

Status

2nd byte

3rd byte

BnH

7EH

mmH

n = MIDI channel number:0H - FH (Ch.1 - 16) mm = mono number:00H - 10H (0 - 16)

*The same processing will be carried out as when All Notes Off is received.

*In Performance mode, the Part Mono/Poly parameter (PERFORM/PART) will change.

POLY (Controller number 127)

Status

2nd byte

3rd byte

BnH

7FH

00H

n = MIDI channel number: 0H - FH (Ch.1 - 16)

*The same processing will be carried out as when All Notes Off is received.

*In Performance mode, the Part Mono/Poly parameter (PERFORM/PART) will change.

System Realtime Message

Timing Clock

Status

F8H

*This message will be received if the Clock Source parameter (SYSTEM/COMMON) is MIDI.

Active Sensing

Status

FEH

*When Active Sensing is received, the unit will begin monitoring the intervals of all further messages. While monitoring, if the interval between messages exceeds 420 ms, the same processing will be carried out as when All Sounds Off, All Notes Off and Reset All Controllers are received, and message interval monitoring will be halted.

System Exclusive Message

Status

Data byte

Status

F0H

iiH, ddH, ......,eeH

F7H

F0H:

System Exclusive Message status

ii = ID number:

an ID number (manufacturer ID) to indicate the manufacturer whose

Exclusive message this is. Roland's manufacturer ID is 41H.

 

ID numbers 7EH and 7FH are extensions of the MIDI standard;

Universal Non-realtime Messages (7EH) and Universal Realtime Messages (7FH).

dd,...,ee = data:

00H - 7FH (0 - 127)

 

F7H:

EOX (End Of Exclusive)

Of the System Exclusive messages received by this device, the Universal Non-realtime messages and the Universal Realtime messages and the Data Request (RQ1) messages and the Data Set (DT1) messages will be set automatically.

Universal Non-realtime System Exclusive Messages

Identity Request Message

Status

Data byte

Status

F0H

7EH, dev, 06H, 01H

F7H

Byte

Explanation

 

F0H

Exclusive status

 

MIDI Implementation

7EH

ID number (Universal Non-realtime Message)

dev

Device ID (dev: 00H - 1FH (1 - 32), the initial value is 10H (17).)

06H

Sub ID#1 (General Information)

01H

Sub ID#2 (Identity Request)

F7H

EOX (End Of Exclusive)

*When this message is received, Identity Reply message (p. 289) will be transmitted.

GM1 System On

Status

Data byte

Status

F0H

7EH, 7FH, 09H, 01H F7H

Byte

Explanation

 

F0H

Exclusive status

 

7EH

ID number (Universal Non-realtime Message)

7FH

Device ID (Broadcast)

09H

Sub ID#1 (General MIDI Message)

01H

Sub ID#2 (General MIDI 1 On)

F7H

EOX (End Of Exclusive)

*When this messages is received, this instrument will turn to the GM1 mode.

*Not received when the Receive GM1 System On parameter (SYSTEM/COMMON) is OFF.

GM2 System On

Status

Data byte

Status

F0H

7EH 7FH 09H 03H

F7H

Byte

Explanation

 

F0H

Exclusive status

 

7EH

ID number (Universal Non-realtime Message)

7FH

Device ID (Broadcast)

09H

Sub ID#1 (General MIDI Message)

03H

Sub ID#2 (General MIDI 2 On)

F7H

EOX (End Of Exclusive)

*When this messages is received, this instrument will turn to the GM2 mode.

*Not received when the Receive GM2 System On parameter (SYSTEM/COMMON) is OFF.

GM System Off

Status

Data byte

Status

F0H

7EH,7F,09H,02H

F7H

Byte

Explanation

 

F0H

Exclusive status

 

7EH

ID number (Universal Non-realtime Message)

7FH

Device ID (Broadcast)

09H

Sub ID#1 (General MIDI Message)

02H

Sub ID#2 (General MIDI Off)

F7H

EOX (End Of Exclusive)

*When this messages is received, this instrument will return to the Performance mode.

Universal Realtime System Exclusive Messages

Master Volume

Status

Data byte

Status

F0H

7FH, 7FH, 04H, 01H, llH, mmH

F7H

Byte

Explanation

 

F0H

Exclusive status

 

7FH

ID number (universal realtime message)

 

7FH

Device ID (Broadcast)

 

04H

Sub ID#1 (Device Control messages)

 

01H

Sub ID#2 (Master Volume)

 

llH

Master Volume lower byte

 

mmH

Master Volume upper byte

 

F7H

EOX (End Of Exclusive)

 

*The lower byte (llH) of Master Volume will be handled as 00H.

*The Master Level parameter (SYSTEM/COMMON) will change.

Master Fine Tuning

Status

Data byte

Status

F0H

7FH,7FH,04H,03H,llH,mmH

F7H

Appendices

285

Page 285
Image 285
Roland XV-5080 owner manual 285